Magnetic-Drive Centrifugal Pump
5 .2 .1 P030 Model
Use the following instructions to rotate the pump head
on the P030 model.
q
2 P030 Discharge Orientations
Vertical Discharge
q
1. Place the motor in an upright position, resting on the
fan end of the motor.
2. Remove the eight screws from the pump housing.
3. Pull the housing away from the motor adapter/
barrier.
4. Rotate the housing 90
the housing and motor adapter/barrier.
5. Push down on the housing to seat it on the motor
adapter/barrier.
6. Reinstall the screws.
EN
w
Horizontal Discharge
w
, aligning the screw holes on
°
5 .2 .2 P045, P048, P075, P100, P137,
P150, and P200 Models
Use the following instructions to rotate the pump head
on the P045, P048, P075, P100, P137, P150, and P200
models.
w
3 P045, P048, P075, P100, P137, P150, and P200 Discharge
Orientations
Vertical Discharge
q
1. Remove the four clamp ring bolts, lock washers, and
flat washers.
2. Rotate the clamp ring 90
clamp ring and motor adapter/barrier.
3. Reinstall the clamp ring bolts, lock washers, and flat
washers.
Installation
q
Horizontal Discharge
w
, aligning the holes on the
°
7