Dometic P062 Installation And Operation Manual

Dometic P062 Installation And Operation Manual

Magnetic-drive centrifugal pump

Advertisement

Quick Links

MAGNETIC-DRIVE PUMPS
P030, P045, P062, P075, P100, P137, P150, P200
Magnetic-Drive Centrifugal Pump
EN
Installation and Operation Manual . . . . . . . .2
WARNING
Cancer and Reproductive Harm
www.P65Warnings.ca.gov
MARINE
Form No. 341460 2022-12-16 | ©2022 Dometic Corporation

Advertisement

Table of Contents
loading

Summary of Contents for Dometic P062

  • Page 1 MARINE MAGNETIC-DRIVE PUMPS P030, P045, P062, P075, P100, P137, P150, P200 Magnetic-Drive Centrifugal Pump Installation and Operation Manual ..2 WARNING Cancer and Reproductive Harm www.P65Warnings.ca.gov Form No. 341460 2022-12-16 | ©2022 Dometic Corporation...
  • Page 2: Table Of Contents

    9 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 date product information, please visit www.dometic.com.
  • Page 3: Supplemental Directives

    NOTICE: Used to address practices not related to • Use only Dometic replacement parts and physical injury. components that are specifically approved for use with the product.
  • Page 4: Intended Use

    2 Intended Use • Keep the drive magnet and impeller assembly away from metal chips or particles, and items with This Dometic Magnetic-Drive (Mag-Drive) Centrifugal magnetic stripes like credit cards and magnetic Pump (also referred to as the “pump” or the “product”) computer media such as floppy discs and hard drives.
  • Page 5: General Information

    • Use for purposes other than those described in this 4 .2 Minimum Flow Rate manual See the table below for the minimum flow rates by Dometic Corporation reserves the right to modify model. appearances and specifications without notice. Model...
  • Page 6: Installation

    Installation Magnetic-Drive Centrifugal Pump 5 Installation Water Line Strainer Seawater Outlet Inlet Flow NOTICE: Failure to obey the following instructions Outlet Flow Seacock (ball valve) could result in damage to the pump or components, and and Scoop-type, cause property damage. A/C Condenser Coil Through-hull Inlet •...
  • Page 7 P150, and P200 Models Use the following instructions to rotate the pump head on the P030 model. Use the following instructions to rotate the pump head on the P045, P062, P075, P100, P137, P150, and P200 models. 2 P030 Discharge Orientations Vertical Discharge...
  • Page 8: Mounting The Pump

    5. Use an appropriate pipe sealant or tape on the service. threads and other piping connections. P062, P075, P100, P137, P150, and P200 pump 6. Tighten all connections, using appropriate tools for models are provided with a provision for a the selected piping materials.
  • Page 9: Connecting A Drain Plug Or Valve (Optional)

    The electrical codes. following instructions explain how to connect an optional drain plug or valve on the P062, P075, P137, Refer to the wiring diagram affixed to the pump. P150, and P200 models.
  • Page 10: Verifying The Rotation Of The Motor

    Maintenance Magnetic-Drive Centrifugal Pump 6 .3 Verifying the Rotation of the • If the pump is used on fluids with solids, high temperatures, or other items that could cause Motor accelerated wear, then this initial examination should be sooner. 1. Allow the motor to run for 1-2 seconds and observe the rotation of the motor fan.
  • Page 11: Disassembling The Pump

    Magnetic-Drive Centrifugal Pump Maintenance 7 .3 Disassembling the Pump 5 Exploded View - P030 6 Exploded View - P045, P062, P075, P100...
  • Page 12 Maintenance Magnetic-Drive Centrifugal Pump 7 Exploded View - P137, P150, P200 Pump Housing Impeller Drive Assembly Barrier O-Ring Outer Drive Magnet Clamp Ring (not Motor Shaft Housing O-Ring Impeller Bushing included on P200) Motor Impeller Thrust Ring Impeller Shaft Clamp O-Ring Foot (not included on P200) Impeller Assembly...
  • Page 13: Inspecting The Pump Components

    2. Insert a 1 in. (25 mm) diameter plastic or wooden shaft through the impeller and press the bushing out. If needed, contact Dometic Customer Support for a pump wear kit or pump wet end replacement kit. 3. Remove the impeller assembly from the arbor press.
  • Page 14: Reassembling The Pump

    Refer to Figure 9, 10, or 11 on page 1514-15 greater, place the pump and motor securely on the (depending on the pump model) for a reassembly floor with the pump head facing up. diagram. 7 .7 Reassembling the Pump 9 P030 Reassembly 10 P045, P062, P075, P100 Reassembly...
  • Page 15 Magnetic-Drive Centrifugal Pump Maintenance 11 P137, P150, P200 Reassembly Pump Housing Impeller Drive Assembly Barrier O-Ring Outer Drive Magnet Motor Shaft Clamp Ring (not Housing O-Ring Impeller Bushing included on P200) Motor Impeller Thrust Ring Impeller Shaft Clamp O-Ring Foot (not included on P200) Impeller Assembly Motor Barrier...
  • Page 16: Troubleshooting

    OF THE LIMITED WARRANTY FREE OF CHARGE, accordance with all applicable national and local CONTACT: regulations. DOMETIC CORPORATION MARINE CUSTOMER SUPPORT CENTER 2000 NORTH ANDREWS AVENUE POMPANO BEACH, FLORIDA, USA 33069 1-800-542-2477...
  • Page 17 Magnetic-Drive Centrifugal Pump Warranty Information...
  • Page 18 Warranty Information Magnetic-Drive Centrifugal Pump...
  • Page 19 Magnetic-Drive Centrifugal Pump Warranty Information...
  • Page 20 YOUR LOCAL YOUR LOCAL DEALER SUPPORT SALES OFFICE dometic .com/dealer dometic .com/contact dometic .com/sales-offices A complete list of Dometic companies, which comprise the Dometic Group, can be found in the public filings of: DOMETIC GROUP AB Hemvärnsgatan 15 SE-17154 Solna Sweden...