General Information; Specifications; Maximum Surface Temperature; Minimum Flow Rate - Dometic P030 Installation And Operation Manual

Magnetic-drive centrifugal pump
Hide thumbs Also See for P030:
Table of Contents

Advertisement

Magnetic-Drive Centrifugal Pump
• Mounting location (directly to floor plates, rails with
vibration isolators to reduce noise, platforms, etc.)
• Suitable mounting hardware for desired installation
or use
• Suitable piping for desired installation or use (for
example: Schedule 80 PVC, CPVC, copper piping,
stainless steel, flexible hose, etc.)
• Single-phase or three-phase electrical wiring
This manual provides all necessary information for
proper installation and operation of the pump. Poor
installation and improper operating procedures will
result in unsatisfactory performance and possible failure.
The manufacturer accepts no liability for damage in the
following cases:
• Faulty assembly or connection
• Damage to the product resulting from mechanical
influences and excess voltage
• Alterations to the product without express permission
from the manufacturer
• Use for purposes other than those described in this
manual
Dometic Corporation reserves the right to modify
appearances and specifications without notice.

3 General Information

I
The images used in this document are for reference
purposes only. Components and component
locations may vary according to specific product
models.
Recommended Tools and Materials
Wire Strippers and Crimper
Weatherproof Wire Nuts
Other hardware sufficient for
secure mounting at desired
location
EN
Phillips-head Screwdriver
Socket Wrenches
• 5/16 in. (8 mm)
• 3/8 in. (9 mm)
• 1/2 in. (13 mm)
• 5/8 in. (16 mm)
• 3/4 in. (19 mm)
Additional Tools and Materials for Optional Steps
Drill Press
7/16 in. Drill Bit
1/4 in. NPT Tap
Arbor Press

4 Specifications

The major pump parts are glass-filled polypropylene for
superior corrosion resistance.
I
For best performance, maintain operation of
this pump within the following specifications.
Additional specifications for each pump are
available online at www.dometic.com.

4 .1 Maximum Surface Temperature

The maximim allowable surface temperature of the
pump is 180 °F (82 °C).

4 .2 Minimum Flow Rate

See the table below for the minimum flow rates by
model.
Model
3450 rpm
P030
0.3 gpm (.9 lpm)
P045
P048
0.5 gpm (1.9 lpm)
P075
P100
P137
4 gpm (15 lpm)
P150
5 gpm (18.9 lpm)
P200
10 gpm (37.8 lpm)
General Information
Waterproof Pipe Sealant or
Tape
Drain Plug or Valve
Waterproof Electrical Tape
Plastic or Wooden Shaft
2900 rpm
0.3 gpm (.9 lpm)
0.5 gpm (1.9 lpm)
3.4 gpm (12.9 lpm)
4.2 gpm (15.9 lpm)
10 gpm (37.8 lpm)
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P045P048P075P100P137P150 ... Show all

Table of Contents