Comelit UT9279M Technical Manual

Comelit UT9279M Technical Manual

Number keypad module
Hide thumbs Also See for UT9279M:

Advertisement

Quick Links

EN
TECHNICAL
MANUAL
Number keypad module Art. UT9279M
Passion.Technology.Design.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UT9279M and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Comelit UT9279M

  • Page 1 TECHNICAL MANUAL Number keypad module Art. UT9279M Passion.Technology.Design.
  • Page 2: Table Of Contents

    • failure to observe the indications and warnings contained in this Manual / Instruction sheet. Comelit Group S.p.A. reserves the right to change the information provided in this Manual / Instruction Sheet at any time and without prior notice. Table of contents Warning ....................
  • Page 3: Description

    Description Module with number keypad for Ultra entrance panel, compatible with all systems. It can be used as a module for calling the user directly when the code is known and for access control with the activation of built-in relays and audio or audio/video module outputs, and system actuators.
  • Page 4: Technical Specifications

    Technical specifications GENERAL DATA Type Modular Product height (mm) Product width (mm) Product depth (mm) Product colour Aluminium Material Polycarbonate, Anodised aluminium Flush mounting Yes, with specific accessory Surface mounting Yes, with specific accessory COMPATIBLE SYSTEMS Simplebus 2 audio/video with power supply unit art. 4888C Simplebus 2 audio/video with power supply unit art.
  • Page 5: Installation

    Installation BLACK CLACK! CLACK! 3 CLACK! CLOSE Module removal...
  • Page 6: Ultra Audio/Video Module Connection

    Ultra audio/video module connection 1210A 1210 SIMPLEBUS2 R GND NO NC UT2020 UT2010 UT2010VC UT9279M 1595 120-230 V SIMPLEBUS1 BLACK SE NO NC UT1010 UT1020 UT1010VC UT9279M 1440 TX TX RX RX NO NC UT8020 UT8010 UT9279M...
  • Page 7: Stand-Alone Connection

    Stand-alone connection 1395 UT9279M Art. 1595 can also be used. Trade function input for enabling key button Local lock-release input Max 20 m. Local door-opener button.
  • Page 8: Programming

    Programming Default configuration Indicator LED The status LED is located behind the key. Indication PARAMETER DEFAULT VALUE mode: Supercode 778899 ◊ Flashing GREEN: code entry in progress Number of characters for opening codes Steady RED: code rejected (active for 3 seconds) Relay paired with opening Flashing RED: keypad locked due to an excessive number Module SE output...
  • Page 9: Programming Via Number Keypad

    Programming via number keypad Creating an access code Deleting all access codes 1. For the default setting, enter the first 77889 1. For the default setting, enter the 77889 5 characters of the supercode first 5 characters of the supercode »...
  • Page 10: Programming General Parameters

    Programming general parameters 10. Set the buzzer volume choose To change the general parameters, you will need to proceed between This function is used to select the sound level for as follows: 0-1-2-3-4-5- the buzzer: 0 minimum level, 9 maximum level. CAUTION: you need to enter ALL the parameters, even 6-7-8-9 Pre-set value: 9...
  • Page 11: Relay Programming

    Relay programming 4. Enter the number corresponding choose to the desired key button operating between 1. For the default setting, enter the first 77889 mode 0-1-2 5 characters of the supercode This parameter defines the role of the “Key” » the LED lights up in yellow button when the value of the “Clock Input”...
  • Page 12: Changing Relay Settings

    Changing relay settings Permanent activation of number keypad module backlight in stand-alone mode By default: 1. For the default setting, enter the first 77889 • the relay activated when a valid access code is 5 characters of the supercode recognised is connected to the SE output for the audio or audio/video module »...
  • Page 13: Programming Via Vip Manager

    Programming via ViP Manager The ViP Manager software used to program the number • Activation of playback of the corresponding audio keypad module using a computer is available on the website message when each button is pressed (e.g. if you press pro.comelitgroup.com.
  • Page 14: Populating The Contacts List

    Populating the contacts list 1. Select Contacts/Contacts 2. Enter the information required (for each contact you need to enter at least one “access code”; enter the “Name” if you also want to pair actions) 3. Press “Write page” to send the data to the number keypad module Name Access code Antonio Rossi...
  • Page 15: System Performance And Layouts

    System performance and layouts For further information regarding system performance and to view installation layouts, click on the system type: • Simplebus2 audio/video with power supply unit 1210/1210A • Simplebus2 audio/video with 4888C...
  • Page 16 C E R T I F I E D M A N A G E M E N T S Y S T E M S w w w . c o m e l i t g r o u p . c o m Via Don Arrigoni, 5 - 24020 Rovetta (BG) - Italy...