Cleanness and maintenance

Cleaning the water inlet filter
Use pointed nose pliers to withdraw the plastic filter. Clean, put back and
secure. These filter should be checked every 6 months or so, or more often if
there are frequent interruptions to the water supply.
Note
The filter must be put back in place after cleaning
Cleaning the water inlet filter
Important:
If the machine is exposed to temperatures below 0°C, certain precautions should be taken.
1. Turn off the water tap.
2. Unscrew the inlet hose.
3. Unhook the drain hose from the rear support and position the end of this hose and that of the inlet
hose in a bowl. Run the spin programme.
4. Disconnect the appliance.
5. Screw the inlet hose and reposition the drain hose.
6. When you intend to start the machine up again, make sure that the room temperature is above 0°C.
The filter should be cleaned every 2 months or so, or
when there is a fault that the "Rinse" and "Spin"LEDs
Note
flickers for A2 series and "E3" is lighted up on the
screen for A5/A8.