• Ensure that all electric cables outside of the device are protected from damage (e.g. caused by animals). Never use the device if electric cables or the power connection are damaged! humidifier B 2 E...
Page 3
• Make sure that the water in the water thank is replaced every 3 days. Otherwise there is a risk of microorganisms growing in the water tank which presents a health hazard if they get into the air or water. humidifier B 2 E...
2. In an emergency, disconnect the device from the mains feed-in: Hold onto the mains plug while pulling the power cable out of the mains socket. 3. Do not reconnect a defective device to the mains. humidifier B 2 E...
On/off switch / nebulizer intensity switch Bottom section Top section with water tank Mains connection (adapter) Cover with carbon filter (air filter) Cover for water filter Float Illumination LED ® SecoSan Stick 10 (optional accessory) Nebulizer membrane Air nozzle Mist nozzle humidifier B 2 E...
Use cable bridges. • Make sure that extension cables are completely unrolled. • Make sure that there are no moisture-sensitive objects in the immediate vicinity of the mist nozzle, since water may condense near the mist nozzle. humidifier B 2 E...
Page 7
• Plug the power adapter into a properly fused mains socket. disconnected from the mains. 1. Remove the cover of the carbon filter (8) with the integrated scented oil tank (16) from the device. 2. Put 2 to 3 drops of scented oil onto the sponge in the scented oil tank (16). humidifier B 2 E...
2. Make sure that the device is neither damp nor wet on the outside. Otherwise wipe it dry. 3. Press the On/off switch (4). ð The LED illumination (11) is illuminated in white/blue. ð The device starts to humidify. Fine water mist leaves the mist nozzle (2). humidifier B 2 E...
• Store the device according to the Transport and storage device is not starting, have the electrics checked by a chapter. specialist company or by Trotec. The device is running, but there is no formation of mist: Available accessories • Check whether the water tank indicator light is illuminated.
Page 10
• Check whether the device is set up in a stable and upright position. The device still does not operate correctly after these checks: Please contact the customer service. If necessary, bring the device to an authorised specialist electrical company or to Trotec for repair. humidifier B 2 E...
Page 12
Clean the water tank Info ® Use the SecoSan Stick by Trotec to provide protection 2. Remove the cover (1). ® from germs in the water. The SecoSan Stick prevents 3. Clean the top section with water tank (6) with a standard the reproduction of germs by means of silver ions.
Page 13
The air filter should be cleaned or replaced in case of heavy soiling. 1. Lightly push against the cover of the carbon filter (8). ð The cover of the carbon filter (8) is unlocked from the bottom section (5). humidifier B 2 E...
Page 14
ð The cover of the carbon filter (8) is unlocked from the bottom section (5). 2. Carefully remove the cover of the carbon filter (8) from the bottom section (5). 3. Now clean the area around the scented oil tank (16). humidifier B 2 E...
Cable length 1.45 m equipment. Sound pressure level (1 m 38 dB (A) distance) Water tank capacity 4 l Dimensions (length x width x 230 x 162 x 295 mm height) Weight 1.5 kg humidifier B 2 E...