B 7 E
EN
OPERATING MANUAL
HUMIDIFIER

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the B7E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Trotec B7E

  • Page 1 B 7 E OPERATING MANUAL HUMIDIFIER...
  • Page 2: Table Of Contents

    Notes regarding the operating manual......... 2 Safety .................. 2 Information about the device.......... 4 B 7 E Transport and storage............ 5 Assembly and installation............. 6 https://hub.trotec.com/?id=45089 Operation ................ 8 Safety Available accessories............ 9 Read this manual carefully before starting or using the Errors and faults.............. 10 device. Always store the manual in the immediate vicinity Maintenance ................ 11...
  • Page 3 • Insert the mains plug into a properly fused mains socket. Intended use • Observe the device's power input, cable length and Only use the device as a mobile humidifier for the humidification intended use when selecting extensions to the power and filtration of room air, while adhering to and following the cable.
  • Page 4: Information About The Device

    Residual risks Information about the device Warning of electrical voltage Device description Work on the electrical components must only be The device B 7 E functions as a humidifier, aroma diffuser and carried out by an authorised specialist company! air cleaner. Warning of electrical voltage The ultrasound technology ensures a pleasant room climate and Before any work on the device, remove the mains plug...
  • Page 5: Transport And Storage

    Transport and storage Note If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device. Transport Before transporting the device, observe the following: • Switch the device off. •...
  • Page 6: Assembly And Installation

    Storage Filling the water tank The water tank (3) should be filled with clear drinking water Before storing the device, observe the following: before first use. • Hold onto the mains plug while pulling the power cable out of the mains socket. Note •...
  • Page 7 4. Now close the lid with air outlet (1). Inserting the air filter Note Do not operate the device without an air filter inserted into the air inlet! Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device.
  • Page 8: Operation

    Switching the device on Operation 1. Make sure that the water tank (3) has been filled with • Avoid open doors and windows. drinking water. 2. Make sure that the device is neither damp nor wet on the • Make sure that there are no moisture-sensitive objects outside.
  • Page 9: Available Accessories

    Night mode Shutdown The control element's sound output is deactivated during night Warning of electrical voltage mode. The display switches off after approx. 40 s and only Do not touch the mains plug with wet or damp hands. switches back on when a button is pressed. •...
  • Page 10: Errors And Faults

    The water mist has a peculiar smell: specialist company or by Trotec. • The device is new. Remove and rinse the water tank. Let the open water tank air for some hours.
  • Page 11: Maintenance

    Maintenance intervals Maintenance Maintenance and care interval before as needed every  at least at least at least at least every start- 3 days every every every annually 2 weeks 4 weeks 6 months Cleaning the water tank Check air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior...
  • Page 12 Info 6. Place the water tank (3) back on the bottom section (4) ® Use the SecoSan  Stick by Trotec to provide protection again and fold the handle (13) back to the side. Now close ® from germs in the water. The SecoSan  Stick prevents...
  • Page 13 Cleaning the nebulizer membrane Cleaning the air filter Depending on the hardness of the drinking water used, deposits The air filter should be cleaned or replaced in case of heavy may form on the nebulizer membrane over time. These could soiling.
  • Page 14 Clean the water filter Activities required after maintenance The water filter should be cleaned in case of heavy soiling. If you want to continue using the device: 1. Carefully remove the cover of the water filter (8) from the • Reconnect the device to the mains. water tank (3).
  • Page 15: Technical Annex

    EU countries on the Power consumption 24 W website https://hub.trotec.com/?id=45090. Otherwise, please contact an official recycling centre for electronic and electrical Mains connection adapter 100 V – 240 V / 50 Hz – 60 Hz equipment authorised for your country.
  • Page 16 Trotec GmbH Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...