• Thank you for purchasing this pump. Take the time
to read the instructions carefully before using this
product. We strongly recommend that you keep this
instruction manual in a safe place for future
reference.
• Please refer to our website and the Products
Center for additional installation and operation
instructions and replacement parts information.
MARKS AND MEANING:
"Danger" indicates
DANGER
an imminent hazard-
ous situation which, if not avoided,
WILL result in death or serious injury.
"Warning" indicates
WARNING
an imminent hazard-
ous situation which, if not avoided,
MAY result in death or serious injury.
"Caution" indicates a
CAUTION
potentially hazardous
situation which, if not avoided, MAY
result in minor or moderate injury.
Models: ANC1000, ANC1500,
ANC2000,, ANCV1000,
ANCV1500 & ANCV2000
1
Models: ANC200, ANC300,
ANC500, ANC750, ANCV200,
ANCV300, ANCV500, ANCV750

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ANC200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ashland ANC200

  • Page 1 MAY result in death or serious injury. “Caution” indicates a CAUTION potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury. Models: ANC200, ANC300, ANC500, ANC750, ANCV200, ANCV300, ANCV500, ANCV750 Models: ANC1000, ANC1500, ANC2000,, ANCV1000, ANCV1500 & ANCV2000...
  • Page 2: General Safety Information

    Each Ashland Pump is individually factory tested to ensure proper performance. Closely following these Make sure lifting handles are securely...
  • Page 3: Specifications

    Solids Handling Pumps Models: ANC200/300/500/750/1000/1500 /2000 & ANCV200/300/500/750/1000/1500 /2000 Specifications IMPORTANT Model Number: 1 Phase Models Prior to installation, record Model Number, Amps: Volts: MFG Date: MFG Date, Amps, Voltage, Phase and HP, 3 Phase Models Phase: from pump nameplate for future reference. Amps L1-2: Volts L1-2: Also record the voltage and current readings...
  • Page 4: Technical Data

    Solids Handling Pumps Models: ANC200/300/500/750/1000/1500 /2000 & ANCV200/300/500/750/1000/1500 /2000 Specifications TECHNICAL DATA To handle up to 3” spherical DESCRIPTION: solids in susspension PHYSICAL DATA: Discharge Size 4” Impeller Type 2-Vane, Enclosed for ANC Series, 9-Vane Vortex for ANCV Series Cable Length 35’ LIQUID HANDLING: Solids Size 3” Spherical Maximum Liquid Temp.
  • Page 5 Solids Handling Pumps Models: ANC200, ANC300, ANC500, ANC750, ANC1000, ANC1500 & ANC2000 Performance 1000 1100 GALLONS PER MINUTE ANC200 PERFORMANCE CHART Total Lift (feet) ANC300 PERFORMANCE CHART ANC500 PERFORMANCE CHART Total Total Lift Lift (feet) (feet) GPM 600 550 370...
  • Page 6 Solids Handling Pumps Models: ANCV200, ANCV300, ANCV500, ANCV750, ANCV1000, ANCV1500 & ANCV2000 Performance 1000 1100 GALLONS PER MINUTE ANCV200 PERFORMANCE CHART Total Lift (feet) GPM 290 200 120 ANCV300 PERFORMANCE CHART ANCV500 PERFORMANCE CHART Total Total Lift Lift (feet) (feet) ANCV750 PERFORMANCE CHART ANCV1000 PERFORMANCE CHART Total...
  • Page 7: Receiving And Installation

    Do not pump out of liquid. Submergence The pump should always be operated in the submerged condition. The sump liquid level should meet the mini- mum recommended submergence levels shown on Ashland Pump Minimum Submergence Level chart (See page 24)
  • Page 8: Installation

    Solids Handling Pumps Models: ANC200/300/500/750/1000/1500 /2000 & ANCV200/300/500/750/1000/1500 /2000 Installation The reading should be 100,000 ohms or greater. If the Discharge Piping Install discharge piping or hose assembly to the pump. measured values are below those indicated above, then Discharge piping should be as short as possible and sized no the pump may have a lower seal failure and require ser- smaller than the pump discharge.
  • Page 9: Installation And Service

    Solids Handling Pumps Models: ANC200/300/500/750/1000/1500 /2000 & ANCV200/300/500/750/1000/1500 /2000 Installation and Service Electrical Connections 3. Name Plate - Record the information from the pump Turn circuit breaker off before name plate for future reference. wiring the pump to the control panel.
  • Page 10 Solids Handling Pumps Models: ANC200, ANC300, ANC500, ANC750, ANC1000, ANC1500 & ANC2000 Installation and Service Oil Replacement Motor Housing Motor Housing Pressure Test: Remove pipe plug from motor housing. If oil has been drained, fill to normal level before per- forming pressure test. Remove pipe plug from motor Drain all oil (if not already done so) from motor housing housing.
  • Page 11 Solids Handling Pumps Models: ANC200/300/500/750/1000/1500 /2000 & ANCV200/300/500/750/1000/1500 /2000 Installation and Service Before any service work is WARNING IMPORTANT! - All parts must be clean before done, disconnect and lock reassembly. Handle seal parts with extreme out electrical power to pump.
  • Page 12 Solids Handling Pumps Models: ANC200, ANC300, ANC500, ANC750, ANC1000, ANC1500 & ANC2000 Installation and Service Installing Pump in Sump Cable Assembly: These pumps are usually installed in concrete or fiber- Check power cord for cracks or damage and replace if glass basins with the lift-out rail system. Figure 2 shows required.
  • Page 13 Solids Handling Pumps Models: ANC200/300/500/750/1000/1500 /2000 & ANCV200/300/500/750/1000/1500 /2000 Installation and Service MOUNTING BRACKET SERVICE POLE OPTION FLASHING ALARM LIGHT WEATHERPROOF CONTROL BOX CORD SEAL CONNECTIONS FOR POWER AND CONTROL CORDS (NOT SHOWN) HINGED ACCESS DOOR ALUM.OR STEEL TOP RAIL SUPPORT...
  • Page 14: Wiring Diagram

    Solids Handling Pumps Models: ANC200/300/500/750/1000/1500 /2000 & ANCV200/300/500/750/1000/1500 /2000 Wiring Diagram WIRING CONNECTIONS 1. All electrical wiring must be in accordance with local 3. All wires should be checked for shorts to ground with code and only qualified electricians should make the an ohmmeter or megger after the connections are installations.
  • Page 15: Troubleshooting

    Solids Handling Pumps Models: ANC200/300/500/750/1000/1500 /2000 & ANCV200/300/500/750/1000/1500 /2000 Trouble Shooting Always disconnect the pump from the electrical power source before handling. If the system fails WARNING to operate properly, carefully read instructions and perform maintenance recommendations. If operating problems persist, the following chart may be of assistance in identifying and correcting them.
  • Page 16 Solids Handling Pumps Models: ANC200, ANC300, ANC500 & ANC750 Repair Parts MOTOR PARTS GROUP MOTOR PARTS GROUP MOTOR PARTS GROUP WET-END PARTS GROUP WET-END PARTS GROUP WET-END PARTS GROUP...
  • Page 17 Solids Handling Pumps Models: ANC200, ANC300, ANC500 & ANC750 Repair Parts List Part Description Part No. for pump models ANC200M2-35 ANC200M3-35 ANC200M4-35 ANC200M5-35 ANC200M6-35 ANC300M2-35 ANC300M3-35 ANC300M4-35 ANC300M5-35 ANC300M6-35 2HP 230V 1PH 2HP 230V 3PH 2HP 460V 3PH 2HP 208V 1PH 2HP 208V 3PH 3HP 230V 1PH 3HP 230 3PH...
  • Page 18 Solids Handling Pumps Models: ANC1000, ANC1500 and ANC2000 Repair Parts MOTOR PARTS GROUP MOTOR PARTS GROUP MOTOR PARTS GROUP MOTOR PARTS GROUP MOTOR PARTS GROUP WET-END PARTS GROUP WET-END PARTS GROUP WET-END PARTS GROUP WET-END PARTS GROUP WET-END PARTS GROUP...
  • Page 19 Solids Handling Pumps Models: ANC1000, ANC1500 and ANC2000 Repair Parts List Part Description Part No. for pump models ANC1000M3-35 ANC1000M4-35 ANC1500M3-35 ANC1500M4-35 ANC2000M3-35 ANC2000M4-35 10HP 230V 3PH 10HP 460V 3PH 15HP 230V 3PH 15HP 460V 3PH 20HP 230V 3PH 20HP 460V 3PH WET-END PARTS GROUP 091ANC007A 091ANC007A...
  • Page 20 Solids Handling Pumps Models: ANCV200, ANCV300, ANCV500 & ANCV750 Repair Parts MOTOR PARTS GROUP MOTOR PARTS GROUP MOTOR PARTS GROUP WET-END PARTS GROUP WET-END PARTS GROUP WET-END PARTS GROUP...
  • Page 21 Solids Handling Pumps Models: ANCV200, ANCV300, ANCV500 & ANCV750 Repair Parts Part Description Part No. for pump models ANCV200M2-35 ANCV200M3-35 ANCV200M4-35 ANCV200M5-35 ANCV200M6-35 ANCV300M2-35 ANCV300M3-35 ANCV300M4-35 ANCV300M5-35 ANCV300M6-35 2HP 230V 1PH 2HP 230V 3PH 2HP 460V 3PH 2HP 208V 1PH 2HP 208V 3PH 3HP 230V 1PH 3HP 230 3PH 3HP 460V 3PH 3HP 208V 1PH 3HP 208V 3PH WET-END PARTS GROUP 091ANCV01A...
  • Page 22 Solids Handling Pumps Models: ANCV1000, ANCV1500 & ANCV2000 Repair Parts MOTOR PARTS GROUP MOTOR PARTS GROUP MOTOR PARTS GROUP MOTOR PARTS GROUP MOTOR PARTS GROUP WET-END PARTS GROUP WET-END PARTS GROUP WET-END PARTS GROUP WET-END PARTS GROUP WET-END PARTS GROUP...
  • Page 23 Solids Handling Pumps Models: ANCV1000, ANCV1500 & ANCV2000 Repair Parts Part Description Part No. for pump models ANCV1000M3-35 ANCV1000M4-35 ANCV1500M3-35 ANCV1500M4-35 ANCV2000M3-35 ANCV2000M4-35 10HP 230V 3PH 10HP 460V 3PH 15HP 230V 3PH 15HP 460V 3PH 20HP 230V 3PH 20HP 460V 3PH WET-END PARTS GROUP 091ANCV09A 091ANCV09A...
  • Page 24 Models: ANCV1000, ANCV1500 & ANCV2000 SUBMERGENCE LEVELS (RAIL MOUNTED PUMPS) ”B“ ”C“ PUMP MINIMUM RECOMMENDED ”A“ ABSOLUTE MINIMUM (RECOMMENDED) SUBMERGENCE LEVEL MODEL SUBMERGENCE LEVEL (AT MAXIMUM FLOW) (AT MAXIMUM FLOW) ANC200 5-1/4“ 22-1/2“ 20-3/8“ ANC300 5-1/4“ 23-3/16“ 21-1/16“ ANC500 6-1/4“ 26-1/8“ 23-5/8“ ANC750 6-1/4“...
  • Page 25 Solids Handling Pumps Models: ANCV1000, ANCV1500 & ANCV2000...
  • Page 26 Ashland Pump shall not be liable for any loss, damage, or expenses resulting from the installation or use of its products other than as expressly set forth in this Limited Warranty. Ashland Pump shall in no event be responsible or liable for the cost of field labor or other charges incurred by any purchaser or user in removing and/or reaffixing any Ashland Pump product, part or component or any temporary pumping or other equipment.
  • Page 27 PUEDE DAR como resultado la muerte o lesiones graves. "Precaución" PRECAUCIÓN indica una situación potencialmente riesgosa que, si no se evita, podría dar como resultado lesiones menores o moderadas. Modelos: ANC200, ANC300, ANC500, ANC750, Modelos: ANC1000, ANC1500, ANC2000, ANC1000,...
  • Page 28 Los daños en los sentido común. cables eléctricos pueden causar descargas, quemaduras IMPORTANTE - Ashland Pump no se hace responsable de pérdidas, o la muerte. Nunca manipule cables de alimentación lesiones o muertes resultantes del incumplimiento de estas conectados con las manos mojadas.
  • Page 29: Especificaciones

    Bombas de manipulación de sólidos Modelos: ANC200/300/500/750/1000/1500/2000 y ANCV200/300/500/750/1000/1500/2000 Especificaciones IMPORTANTE :Número de modelo Modelos de 1 fase Antes de la instalación, anote :Amperes :Voltios :Fecha de fabricación el número de modelo, Fecha de Modelos de 3 fases fabricación, Amperes, Voltaje, Fase...
  • Page 30 Bombas de manipulación de sólidos Modelos: ANC200/300/500/750/1000/1500/2000 y ANCV200/300/500/750/1000/1500/2000 Especificaciones DATOS TÉCNICOS :DESCRIPCIÓN Para manejar sólidos esféricos de hasta 3" en suspensión :DATOS FÍSICOS Tamaño de la descarga "4 Tipo de impulsor paletas, Cerrado para la serie ANC, Vórtice de 9 paletas para la serie ANCV 2 Longitud del cable :MANEJO DE LÍQUIDOS...
  • Page 31 Models: ANC200, ANC300, ANC500, y ANCV200/300/500/750/1000/1500/2000 ANC750, ANC1000, ANC1500 & ANC2000 Desempeño Performance 1000 1100 GALLONS PER MINUTE GALONES POR MINUTO GRÁFICO DE RENDIMIENTO DE ANC200 ANC200 PERFORMANCE CHART Elevación Total total Lift (feet) ((pies GRÁFICO DE RENDIMIENTO DE ANC300 GRÁFICO DE RENDIMIENTO DE ANC500...
  • Page 32 Bombas de manipulación de sólidos Solids Handling Pumps Modelos: ANC200/300/500/750/1000/1500/2000 Models: ANCV200, ANCV300, ANCV500, y ANCV200/300/500/750/1000/1500/2000 ANCV750, ANCV1000, ANCV1500 & ANCV2000 Desempeño Performance 1000 1100 GALLONS PER MINUTE GALONES POR MINUTO GRÁFICO DE RENDIMIENTO DE ANCV200 ANCV200 PERFORMANCE CHART Elevación...
  • Page 33 La bomba debe funcionar siempre en condiciones de inmersión. El nivel de líquido del sumidero debe cumplir con los niveles de inmersión mínimos recomendados que se muestran en la tabla de Nivel mínimo de inmersión de .(Ashland Pump (vea la página 24...
  • Page 34: Instalación

    Bombas de manipulación de sólidos Modelos: ANC200/300/500/750/1000/1500/2000 y ANCV200/300/500/750/1000/1500/2000 Instalación Tubería de descarga La lectura debe ser de 100,000 ohmios o más. Si los valores Instale en la bomba la tubería de descarga o el conjunto de medidos están por debajo de los antes indicados, la bomba mangueras.
  • Page 35: Instalación Y Servicio

    Bombas de manipulación de sólidos Modelos: ANC200/300/500/750/1000/1500/2000 y ANCV200/300/500/750/1000/1500/2000 Instalación y servicio Conexiones eléctricas Mantenimiento Apague el disyuntor antes de cablear la bomba al Realice las siguientes comprobaciones cuando la bomba se .panel de control retire de operación o cuando el rendimiento de la bomba :disminuya Inspeccione las cámaras del motor y de sellado a fin...
  • Page 36 Bombas de manipulación de sólidos Modelos: ANC200/300/500/750/1000/1500/2000 y ANCV200/300/500/750/1000/1500/2000 Instalación y servicio :Prueba de presión de la carcasa del motor Reemplazo de aceite de la carcasa del motor Si se ha drenado el aceite, llene hasta el nivel normal antes .Quite el tapón del tubo de la carcasa del motor...
  • Page 37 Bombas de manipulación de sólidos Modelos: ANC200/300/500/750/1000/1500/2000 y ANCV200/300/500/750/1000/1500/2000 Instalación y servicio Antes de realizar cualquier Sello interno ADVERTENCIA trabajo de servicio, desconecte Limpie y aceite (utilice aceite dieléctrico de enfriamiento del .y bloquee la energía eléctrica hacia la bomba motor limpio) la cavidad del sello en la carcasa del mismo.
  • Page 38 Bombas de manipulación de sólidos Modelos: ANC200/300/500/750/1000/1500/2000 y ANCV200/300/500/750/1000/1500/2000 Instalación y servicio :Conjunto de cables Instalación de la bomba en el sumidero Compruebe si hay grietas o daños en el cable de alimentación Estas bombas se instalan generalmente en depósitos de .y sustitúyalo de ser necesario...
  • Page 39 Bombas de manipulación de sólidos Solids Handling Pumps Modelos: ANC200/300/500/750/1000/1500/2000 Models: ANC200/300/500/750/1000/1500 /2000 y ANCV200/300/500/750/1000/1500/2000 & ANCV200/300/500/750/1000/1500 /2000 Instalación y servicio Installation and Service ABRAZADERA DE MOUNTING INSTALACIÓN BRACKET SERVICE OPCIÓN DE POSTE POLE OPTION DE SERVICIO LUZ DE ALARMA PARPADEANTE...
  • Page 40 Bombas de manipulación de sólidos Solids Handling Pumps Modelos: ANC200/300/500/750/1000/1500/2000 Models: ANC200/300/500/750/1000/1500 /2000 y ANCV200/300/500/750/1000/1500/2000 & ANCV200/300/500/750/1000/1500 /2000 Diagrama de cableado Wiring Diagram CONEXIONES DEL CABLEADO Después de que se hagan las conexiones, se deben revisar Todo el cableado eléctrico debe estar de acuerdo con todos los cables con un ohmímetro o megóhmetro a...
  • Page 41: Identificación Y Resolución De Problemas

    Bombas de manipulación de sólidos Modelos: ANC200/300/500/750/1000/1500/2000 y ANCV200/300/500/750/1000/1500/2000 IDENTIFICACIÓN Y RESOLUCIÓN DE PROBLEMAS ADVERTENCIA Desconecte siempre la bomba de la fuente de alimentación eléctrica antes de manipularla. Si el sistema no funciona correctamente, lea atentamente las instrucciones y cumpla con las recomendaciones de mantenimiento. Si los .problemas de funcionamiento persisten, la tabla siguiente puede ser de ayuda para identificarlos y corregirlos...
  • Page 42 Bombas de manipulación de sólidos Solids Handling Pumps Modelos: ANC200, ANC300, ANC500 y ANC750 Models: ANC200, ANC300, ANC500 & ANC750 Piezas para reparación Repair Parts MOTOR PARTS GROUP MOTOR PARTS GROUP MOTOR PARTS GROUP GRUPO DE PIEZAS DEL MOTOR GRUPO DE PIEZAS DE EXTREMO...
  • Page 43: Repair Parts List

    Bombas de manipulación de sólidos Solids Handling Pumps Modelos: ANC200, ANC300, ANC500 y ANC750 Models: ANC200, ANC300, ANC500 & ANC750 Lista de piezas para reparación Repair Parts List °.N Descripción de la pieza Part Description N.° de pieza para modelos de bombas Part No.
  • Page 44: Repair Parts

    Bombas de manipulación de sólidos Solids Handling Pumps Modelos: ANC1000, ANC1500 y ANC20000 Models: ANC1000, ANC1500 and ANC2000 Piezas para reparación Repair Parts MOTOR PARTS GROUP MOTOR PARTS GROUP MOTOR PARTS GROUP MOTOR PARTS GROUP MOTOR PARTS GROUP GRUPO DE PIEZAS DEL MOTOR GRUPO DE PIEZAS DE EXTREMO WET-END PARTS GROUP WET-END PARTS GROUP...
  • Page 45 Bombas de manipulación de sólidos Solids Handling Pumps Modelos: ANC1000, ANC1500 y ANC2000 Models: ANC1000, ANC1500 and ANC2000 Lista de piezas para reparación Repair Parts List Part Description Part No. for pump models °.N N.° de pieza para modelos de bombas Cant.
  • Page 46 Bombas de manipulación de sólidos Solids Handling Pumps Modelos: ANCV200, ANCV300, ANCV500 y Models: ANCV200, ANCV300, ANCV500 & ANCV750 ANCV750 Repair Parts Piezas para reparación MOTOR PARTS GROUP MOTOR PARTS GROUP MOTOR PARTS GROUP GRUPO DE PIEZAS DEL MOTOR GRUPO DE PIEZAS DE EXTREMO WET-END PARTS GROUP WET-END PARTS GROUP WET-END PARTS GROUP...
  • Page 47 Bombas de manipulación de sólidos Solids Handling Pumps Modelos: ANCV200, ANCV300, ANCV500 y ANCV750 Models: ANCV200, ANCV300, ANCV500 & ANCV750 Lista de piezas para reparación Repair Parts Part Description Part No. for pump models °.N Descripción de la pieza N.° de pieza para modelos de bombas Cant.
  • Page 48 Bombas de manipulación de sólidos Solids Handling Pumps Modelos: ANCV1000, ANCV1500 y ANCV2000 Models: ANCV1000, ANCV1500 & ANCV2000 Piezas para reparación Repair Parts MOTOR PARTS GROUP MOTOR PARTS GROUP MOTOR PARTS GROUP MOTOR PARTS GROUP MOTOR PARTS GROUP GRUPO DE PIEZAS DEL MOTOR GRUPO DE PIEZAS DE EXTREMO WET-END PARTS GROUP WET-END PARTS GROUP...
  • Page 49 Bombas de manipulación de sólidos Solids Handling Pumps Modelos: ANCV1000, ANCV1500 y ANCV2000 Models: ANCV1000, ANCV1500 & ANCV2000 Piezas para reparación Repair Parts °.N N.° de pieza para modelos de bombas Descripción de la pieza Part Description Part No. for pump models Cant.
  • Page 50 RECOMENDADO DE SUBMERGENCE LEVEL SUBMERGENCE LEVEL ABSOLUTO DE MODEL (RECOMENDADO) (AT MAXIMUM FLOW) (AT MAXIMUM FLOW) BOMBA INMERSIÓN (EN EL FLUJO INMERSIÓN (EN EL MÁXIMO) FLUJO MÁXIMO) ANC200 5-1/4” 22-1/2” 20-3/8” ANC200 5-1/4“ 22-1/2“ 20-3/8“ ANC300 5-1/4” 23-3/16” 21-1/16” ANC300 5-1/4“...
  • Page 51 Bombas de manipulación de sólidos Modelos: ANCV1000, ANCV1500 y ANCV2000 Especificaciones de par de apriete de las sujeciones (Instalación en seco) Sujetadores SST Basado en pruebas de laboratorio reales de sujetadores secos o casi secos Par de apriete Par de Par de Par de Roscas por...
  • Page 52 Ashland Pump o a cualquier otro lugar que Ashland Pump pueda designar, flete prepagado. En ausencia de una prueba adecuada de la fecha de compra, la fecha de entrada .en vigor de esta garantía se basará...

Table of Contents