Download Print this page

Diagnostic Indicators - MTS Systems MPA-460 ANF3/8031 Manual

Brushless servo amplifier

Advertisement

Diagnostic Indicators

Mark (RED)
This is an output that comes ON at the resolver zero position and can be used in
conjunction with alignment procedures. The zero position is about .5 degrees.
Current (BI-COLOR)
This is a bi-color LED that can be either red or green as a function of load. Red indicates
positive torque and green indicates negative torque. The intensity increases with load.
There are eight faults that will disable the amplifier:
LED
CONTINUOUS
STATOR SHORTS
AMPLIFIER THERMAL An 85° C thermostat is mounted to the amplifiers IGBT
FEEDBACK WIRING
MOTOR THERMAL or
OVERSPEED
HI-BUS
RESET
LIMIT
Power (GREEN)
If logic +5 Vdc is ON, then this LED is ON.
14
INDICATION
If a load condition exists that causes the amplifier to
produce more than its continuous rating, this fault
occurs.
If stator shorts or most major wiring errors of the stator
occur, this fault occurs.
heat sink. If an excess temperature is sensed, this fault
occurs.
For most resolver wiring errors, defective resolvers or
tracking rate errors caused by the resolver, this fault
occurs.
If an excess thermal or adjustable condition exists in the
motor, this fault occurs.
If excess DC voltage or a failure of the shunt circuit
occurs, this fault occurs.
During the first second of power up or if the reset input
is active, this LED will be ON.
If either of the limit inputs are ON, This LED will be ON.

Advertisement

loading