Page 2
A Summary of Changes to the MPA-03/06-SL manual (575-00031) Rev A to Rev B (June 1999) Removed all references to “Custom Servo Motors”. • Corrected “Simulated Encoder Signals” section. • Rev B to Rev C (January 2001) Changed the first paragraph under “Warranty and Service” to read: •...
T A B L E O F C O N T E N T S Application ..........................1 Unpacking and Inspection ......................1 Warranty and Service ....................... 1 Service Under Warranty ....................2 Non-Warranty Service ....................2 General Provisions ...................... 2 Introduction ..........................
M P A - 0 3 / 0 6 S L B R U S H L E S S S E R V O A M P L I F I E R S Application This manual is designed to help you install the MaxPlus™ MPA-03/06SL amplifier. Unpacking and Inspection Carefully unpack the amplifier and inspect it for visible damage.
Warranty and Service (continued) Service Under Warranty • Return your defective unit, freight prepaid, and it will be repaired and returned within two weeks of receipt via regular UPS, freight prepaid. • Upon request, a factory-repaired replacement unit will be sent via regular prepaid UPS, within 4 working days.
Introduction These amplifiers are designed to be used with high performance brushless servo motors. Care has been taken to assure robust operation. Design consideration for electrical transients have been implemented on the ac power input and all of the I/O lines. The amplifier operates over an ac voltage range of 80 to 260 Vac from 45 to 65 Hz.
MPA-03/06SL Mechanical Footprint "L" bracket design can be mounted either flat or right angle. TOP VIEW 11.6 11.4 *2.8 6.38 All dimensions in inches A = .178 diameter thru hole Dimensions: 11.6L X 6.38W X 3.0H Max *The AN-06 is 0.8 taller than the AN-03...
Base Plate Mounting Options Bottom View 0 .42 5.22 6.38 11.6 11.4 9.96 All dimensions in inches A = .178 diameter thru hole B = #10-32 standard pem nut 1.16...
Feedback Wiring REF GND SIN GND COS GND THERM SWITCH THERM GND SHIELD WINDING THERM RESP 100% SHIELDED REFERENCE FREQUENCY 2KHZ 20-25 VP-P SIN/COS 0-5V MAX RMS NOTE 100% shielded cable is foil and braid. The pairs do not have to be twisted. The resolver wiring should not be run adjacent to any non- shielded high voltage wires, such as the motor wires (RST).
Motors and Commutation The amplifier can commutate 4-pole, 6-pole, 8-pole, and brush motors in its standard configuration and other factory options are practical. JP3 and JP4 allow for configuration changes. Drives are shipped set for 6-pole operation. Never change these jumpers with power on.
Diagnostic Indicators MOTOR THERMAL FEEDBACK WIRING SHORTS POWER ON CONTINUOUS SIG BAL RESP CUR There are four faults that will reduce amplifier current to zero. INDICATION CONTINUOUS If a load condition exists that causes the amplifier to produce more than its continuous rating, this fault occurs.
I/O Wiring and Descriptions The amplifier has three inputs and two outputs. These inputs and outputs are designed to interface to a 24-volt logic system. The amplifier is shipped so that the operation of the inputs are as follows. With no wires connected to VEL/TORQUE, ENABLE, or START, the amplifier is disabled and normal operation will not occur.
Simulated Encoder Option TOP VIEW ENC01.PCB DB9 FEMALE CONNECTOR MARK LED The ENC01.PCB plugs into the drive mating connector and is held in position with two #6-32 screws. For external counting or position control, a 9-pin D type female connector that has TTL differential outputs is provided.
Simulated Encoder Connector 9-PIN DB9 FEMALE 5 4 3 2 1 PIN 1 = A\ PIN 6 = A PIN 2 = B PIN 7 = B\ PIN 3 = M PIN 8 = M\ PIN 4 = GND PIN 9 = GND PIN 5 = SHIELD 9 8 7 6 The phase relationship of channels A, B and M for CW rotation:...
Page 17
Bus Voltage Limit The motors maximum no load speed is limited by its KE. The simple guideline is to divide the KE into the AC input voltage. AC Input -------------- = MAX no load speed KE Motor This maximum speed must be derated by .75 at full load. TAC Gradient Limit If the drive is being used in the velocity mode, the TAC gradient, as determined by the R-D converter resolution jumpers, would limit speed.
Analog Input and Adjustments There is one analog input channel for command. This has differential inputs and is summed with a TAC feedback differential amplifier that controls velocity if the Velocity Mode is selected. Normal operation of the command signal is to apply a + voltage (pin #9) with respect to GND (pin #11) and get clockwise rotation of the shaft.
AC Input and Internal Protection A branch circuit disconnect must be provided in front of the drive. Model Single Phase MPA-03 SL 5 amps MPA-06 SL 10 amps AC power wiring must be consistent with any local codes, national electric codes, and be able to withstand the voltage current ratings applied.
The locked rotor stator current is equal to the drive's continuous rating, and for either low speed or locked rotor conditions, the stator must withstand this continuous rating. Model Locked Rotor MPA-03 SL 3 amps MPA-06 SL 6 amps It is acceptable and recommended that four conductor shielded cable be used.
Start-Up Once normal wiring is verified, power can be applied to the amplifier. Assure the input settings are what are required. Jumper default settings are for 6-pole motors. The ENABLE Input will disable the drive if it is not connected. The CUR and RESP adjustments are turned down (CCW).
Typical Wiring RESOLVER CONNECTOR RED/WHT RED/WHT REF GND YEL/WHT YEL/WHT YELLOW YELLOW BLUE SIN GND BLUE COS GND BLACK BLACK THERM SWITCH BLU/WHT THERM SWITCH THERM SWITCH BLK/WHT THERM SWITCH SHIELD SHIELD THE RESOLVER CABLE IS 100% SHIELDED (FOIL & BRAID) WITH A DRAIN WIRE.