Jumper Selections - MTS Systems MAXPLUS 306 Manual

Option spindle amplifier

Advertisement

Jumper Selections

RESET
I/O WIRING
JP19
JP3
The position of this jumper determines the kind of dc voltage proportional to current that is a
diagnostic signal at the (CUR) output of the I/O connector. With the shorting pin in the bipolar
position, the output CUR signal is plus for positive current and minus for negative current. The
voltage range is plus and minus ten where ten equals the amplifiers continuous current. With
the jumper in absolute, the proportional voltage is always positive for either plus or minus
motor current.
enabled
The position of this jumper determines whether the shaft will turn at 1 rps when PIN 13 is
grounded.
SIMULATED
ENCODER
JP11
JP3
BI-POLAR
ABSOLUTE (STANDARD)
SPINDLE ORIENT ENABLE
JP19
disabled
(STANDARD)
FEEDBACK WIRING
DIP 1
ON
1 2 3 4
JP9
15

Advertisement

loading

This manual is also suitable for:

Mpa-50-306