Kohler K-10430 Installation Manual page 8

Kitchen sink faucets
Table of Contents

Advertisement

Available languages

Available languages

Handle
Styles
vary.
Bonnet
Indexer
Splines
7. Water Temperature Adjustments
NOTE: Before adjusting the water temperature, ensure that the
handle is turned all the way to the left. This is the maximum hot
position.
Remove the plug button, screw, handle, and bonnet.
Position the indexer to stop the valve stem at the desired
maximum temperature.
Turn the water on and rotate the valve stem to full hot to confirm
the setting.
Reinstall the handle and bonnet onto the faucet body.
Reposition and tighten the setscrew.
Reinstall the plug button.
1036178-2-D
Setscrew
Plug
Button
Valve Stem
8
Kohler Co.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

K-r10434K-r10430

Table of Contents