Main Control Board Resistance Checks
(Use if unable to verify operation in Service Mode)
Flame Detector
Checked from the yellow 2-pin connector with blue and gray wires.
Unplug the connector and measure between the blue and gray wires.
The flame detector should read continuity (0 ohms).
Igniter
Checked between the yellow 2-pin connector and the black relay.
Unplug the yellow connector and measure from the blue wire on the connector
to the blue wire on the black relay. Resistance should be approximately 182
ohms.
Moisture Sensor (Sensor rods)
Checked from the white 6-pin connector with green, blue, red and orange wires.
Unplug the connector and measure between the blue and orange wires.
There should be resistance when placing a damp cloth across the sensor rods.