Download Print this page
Delta PMC Series Instruction Manual

Delta PMC Series Instruction Manual

Advertisement

Quick Links

Instruction Manual
1. Safety Instructions
To ensure sufficient convection cooling, always maintain a safety distance of
≥ 20mm from all ventilated surfaces while the device is in operation.
The device is not recommended to be placed on low thermal conductive
surface, for example, plastics.
Note that the enclosure of the device can become very hot depending on the
ambient temperature and load of the power supply. Do not touch the device
while it is in operation or immediately after power is turned OFF. Risk of burning!
Do not touch the terminals while power is being supplied. Risk of electric shock.
Prevent any foreign metal, particles or conductors to enter the device through
the openings during installation. It can cause: Electric shock; Safety Hazard;
Fire; Product failure
Warning: When connecting the device, secure Earth connection before
connecting L and N. When disconnecting the device, remove L and N
connections before removing the Earth connection.
Nominal input voltage: 100-240Vac or 125-250Vdc
Voltage range: 90-264Vac or 120-375Vdc
2. Device Descriptions
Refer to Fig. 1.:
䐟 Input & Output terminal block connector
䐠 DC voltage adjustment potentiometer
䐡 DC OK control LED (Green)
3. Installation of the Device
Refer to Fig. 2.:
䑵 Mounting holes for power supply assembly onto the mounting surface. The
power supply shall be mounted on minimum 2 mounting holes using M3 screw
minimum 5mm length.
䑶 This surface belongs to customer's end system or panel where the power
supply is mounted.
䑷 Connector
Use flexible cable (stranded or solid), AWG No. 20-14. The torque at the
Connector shall not exceed 13 Kgf.cm. The insulation stripping length should
not exceed 0.275" or 7mm (Refer to Fig. 3).
4. Installation of Mounting Accessories
Refer to Fig. 4.:
Only use M3 screw ≤ 6mm through the base mounting holes. This is to keep a
safety distance between the screw and internal components.
Recommended mounting tightening torque: 4~8 Kgf.cm.
REV.01
Ventilated Surface
Base Surface
Fig. 1. Device Descriptions
Side Mounting (Vertical)
Base Mounting (Vertical)
A
A
A
A
A
A
C
C
C
C
C
C
B
B
B
Fig. 2. Mounting Orientation
7 mm
Lug
Stripped wire
Fig. 3. Wire Type
PMC-05V050W1AA
Side Surface
Top Surface
3
2
1
Side Mounting (Horizontal)
B
B
B
A
A
A
C
B
B
B
Mounting
Chassis of
accessories
the device
Mounting
screw
6mm max.
Fig. 4. Mounting Screw
www.DeltaPSU.com
C
C

Advertisement

loading

Summary of Contents for Delta PMC Series

  • Page 1 Instruction Manual PMC-05V050W1AA 1. Safety Instructions Side Surface • To ensure sufficient convection cooling, always maintain a safety distance of ≥ 20mm from all ventilated surfaces while the device is in operation. Ventilated Surface • The device is not recommended to be placed on low thermal conductive Top Surface surface, for example, plastics.
  • Page 2 PMC-05V050W1AA 使用說明書 使用说明书 1. 安全規範 1. 安全规范 與通風表面保持至少 20mm 的安全距離,以確保對流冷卻充分。 与通风表面保持至少 20mm 的安全距离,以确保对流冷却充分。 • • • 本產品不適合擺放在低熱導體,例如: 塑膠。 • 本产品不适合摆放在低热导体,例如: 塑胶。 • 受環境溫度及產品負載的影響,本機外殼溫度會很高,因此在上電時或切斷電 • 受环境温度及产品负载的影响,本机外壳温度会很高,因此在上电时或切断电 源後短時間內不要觸摸本機,以免燙傷。 源后短时间内不要触摸本机,以免烫伤。 • 請勿在上電時觸摸連接端子,以防電擊危險。 • 请勿在上电时触摸连接端子,以防电击危险。 • 安裝過程中,應避免金屬元件或金屬導體通過空隙或通風孔進入到產品內, • 安装过程中,应避免金属元件或金属导体通过空隙或通风孔进入到产品内, 否則會引起下列狀況。 否则会引起下列状况。 -電擊;安全危害;火災;產品異常 -电击;安全危害;火灾;产品异常 警告: 在連接產品電源供應時,產品必須先接地然後才接 L 和 N。當要解開電源 警告: 在连接产品电源供应时,产品必须先接地然后才接...

This manual is also suitable for:

Pmc-05v050w1aa