Transit Bracket
Removal
All manuals and user guides at all-guides.com

Connecting to the Water Supply

Hot and Cold Fill Connection
1. Connect the straight end of the supplied RED or GREY hose to
1. Remove
the HOT water supply tap (Fig 1). Connect the straight end of
the 3
the supplied BLUE hose to the COLD water supply tap.
screws from
2. Hand tighten connectors sufficiently to ensure water does not
back of
leak from the hose connections.
work top
3. Before connecting each of the hoses to the appliance, confirm
lid.
the water supply is flowing by holding the free end of each
hose in a bucket, turn the relevant water supply taps on and
then off.
4. Connect the angled end of the RED or GREY hose to the white
2. From the
plastic inlet valve marked 'H' (Fig 2) and the angled end of the
rear of
BLUE hose to the white plastic inlet valve marked 'C' at the back
appliance,
of the appliance.
grip the
5. Hand tighten connectors sufficiently to ensure water does not
sides of the
leak from the hose connections.
work top
lid, lift, slide
6. Turn on the water supply taps and check for leaks from the connectors. In the event
and pull
of a leak, turn off supply tap, remove connector and check that the sealing washer is
towards
in place. Refit the connector and tighten. Turn on water supply taps.
you to
remove.
Cold Fill Only Connection
A Cold Fill Adaptor is available from your local Creda authorised Service
3. Remove
Centre.
1 screw and
1. Connect angled end of supplied hoses to hot and cold inlets
clamp.
at the back of appliance
Retain for
future use.
2. Connect straight end of hoses to cold fill adaptor.
3. Connect adaptor to cold water supply.
NOTE: Hand tighten sufficiently to ensure water is not leaking from
the tap hose connections.
4. Remove 2
screws and
Fill Hoses
transit
Ensure the supplied hoses are not kinked when connected.
bracket.
2m long extension fill hoses are available from your local retailer
Retain for
or Genuine Parts and Accessories UK 08709 077 077.
future use.
Water Pressure
Incoming hot and cold water pressure should be between 3 and 150
5. Slide and
psi (21 - 1034 Kpa).
push work
The temperature of the incoming household hot water supply should ideally be 60°C and
top lid into
no higher than 70°C as this could cause damage to both your laundry and appliance.
position
ensuring it
is located
Methods of Plumbing
on the
console
The water supply taps must be easily accessible when the appliance is installed. Your
correctly.
taps should be in good condition or it may leak when turned full on. Mixer taps are
unsuitable, if you have them you will need to use permanent plumbing. Adaptors are
required to connect to sink taps.
6. Replace
Permanent Plumbing
the 3
screws into
There must be taps or stopcocks so that the water supply can be turned off, isolating
the back of
the appliance from the household supply.
the work
top lid.
Existing Plumbing
If you have an existing installation please check that this includes taps or stopcocks to
isolate the appliance. The appliance must be connected to the water supply using
the new hose set supplied, old hose sets should not be used.

Removing the Polystyrene Pyramid

After removing the packaging from the machine, ensure that the polystyrene pyramid
(shown at the side) has come away from the underside of the machine, with the
polystyrene base.
If it has not come away, remove it by tilting the machine backwards until the pyramid can
be seen and then remove.
Fig 1
Fig 2
Cold Water Supply
Fig. 3
Inlet to machine
Inlet to machine
Fig. 4
Cold
Water
Supply
Inlet to machine
3

Advertisement