b) Make sure that the environment in which you will be working has dedicated ventilation.
c) Protect your nose and mouth with a dedicated mask.
• Do not use the compressor when the electrical cable or the plug is damaged, and instruct
an authorised Support Service to replace them with an original part.
• When the compressor is placed on a surface higher than the floor, it should be secured to
prevent it from falling down during operation.
• Do not put objects or your hands in the
protective covers to avoid physical damage and damage to the compressor.
• Do not use the compressor as a blunt instrument against persons, objects or animals in
order to prevent serious damage.
• If the compressor is no longer in use, always take the plug out of the plug socket.
• Always make sure that compressed-air hoses are used for compressed air and which are
characterised by a maximum pressure adjusted to that of the compressor. Do not try to repair
the hose if it is damaged.
3. USE
The compressor is used as a power supply for pneumatic machines.Only used indoors!
NB: The information you will find in this manual has been written to assist the operator in
the use and maintenance of the compressor. Some illustrations in this manual show details
which may differ from those of your compressor.
This compressor must be grounded while in use to protect the operator from electric
shock. The compressor connects to the correct ground contact. The green / or green and
yellow / cord in the cord is the ground wire. Never connect green / or green and yellow / strand
to other colors of wires.
Extension cord
Only use extension cords that match the compressor plug. Replace or repair a damaged
cable. Make sure your extension cable is in good condition.
When using an extension cord, use one of the right size. Using the wrong extension cord
will cause a voltage drop, resulting in loss of power and overheating. The table shows the
correct size for use depending on the length of the cable and the amp plate. If in doubt, use
the next extension cord.
Maximum length of 20 meters cable with three-phase compressor. The diameter of the
extender must be proportional to its length.
CV
2-3.4
5.5
7.5
10
Electrical components
Three-phase compressors must be installed by a specialist technician. Three-phase
compressors are shipped without plug. Connect with the plug, With the mounting screw and
the mounting bracket to the cable (described in the table below).
kW
1.5-2.2-3
4
5.5
7.5
380/400 V
1.5 mm
2
2 mm
2
2.5 mm
2
4 mm
2
15