If a fault occurs, inspect the device for the following errors and take appropriate measures. If
there are other undefined errors, please contact Siemens Support
support.industry.siemens.com/cs/start?lc=en-US).
Error detection
Device does not respond, all LEDs are
off
The red LED (RUN) flashes once per
second.
The yellow LED (RADIO) is off.
The blue LED (SERVER) is off.
The blue LED (SERVER) flashes.
System Manual, 04/2019, C79000-G8976-C577-01
Dimension drawing SIMATIC RTLS4330A - All dimensions specified in millimeters
Cause of the error
The device is not connected or the pow‐
er supply unit is not switched on.
Undervoltage on the device
Device is not connected to the Locating
Manager.
Device has no network connection
(LAN)
Device is not connected to the Locating
Manager.
5.2 SIMATIC RTLS4330A
(https://

Troubleshooting

Check the supply voltage of the device.
Check the supply voltage of the device.
Switch on Locating Manager.
Check local network,
Check firewall
Activate Locating Manager