Connection of the cables
Make sure that the wiring is correct before you start up the device.
Connection of the antenna
Connect the antenna to the RP SMA connection (P2). The device must not be operated without
an antenna. The device must be turned off or disconnected from the power to change or
remove the antenna.
The antennas of all wireless devices must be equally aligned.
Supply voltage
When the supply voltage is connected at the "Power" input, all LEDs light briefly for a moment.
The POWER LED lights up permanently in green as soon as voltage is present.
Check whether the rated voltage of the power supply corresponds to the values in the section
"Technical specifications".
7.5.3
Technical specifications
Table 7-13
Technical specifications of the transponder RTLS4460T
Product name
Wireless frequencies
Wireless method
Transmission speed
Operating frequency rated value
Transmit power
Range
Accuracy of the localization
Chirp bandwidth
Range with 1 Mb
Supply voltage, power consumption
Supply voltage
Energy intake
Digital inputs and outputs
Input voltage
System Manual, 04/2019, C79000-G8976-C577-01
SIMATIC RTLS4460T
IEEE 802.15.4a nanoLOC - Chirp Spread Spectrum (CSS)
1 Mbps
2400 ... 2480 MHz
Max. 100 mW, can be set
Max. 1000 m
1.5 m
80 MHz
Inside maximum 90 m
Outside maximum 1000 m (typical 500 m)
24 V DC
Max. 1.6 W / 0.06 A
0 to 24 V DC
Transponder
7.5 SIMATIC RTLS4460T
6GT2700-6CE02