Antenna cable, 3 m
Flexible connecting cable (e.g. for connecting an antenna to an access
point)
1 m
2 m
5 m
7.5.1.3
Pin assignment
P1 - Plug-in connector for power, digital output
16-pin plug-in connector WR-MPC4
0.33 mm
Pin
1
2
3
4
5
6
7
8
Connector
9
10
11
12
13
14
15
16
System Manual, 04/2019, C79000-G8976-C577-01
open 1.31 mm
2
2
Description
not applicable
Digital input 7
Digital input 5
Digital input 3
Digital input 1
CAN high
Digital output 1
24 V DC (e.g. terminal 30)
Description
not applicable
Digital input 8
Digital input 6
Digital input 4
Digital input 2
CAN low
Digital output 2
GND (e.g. terminal 31)
Transponder
7.5 SIMATIC RTLS4460T
Article number
6GT2791-6AH30
6XV1875-5CH10
6XV1875-5CH20
6XV1875-5CH50
159