4-Way Multipoise Two-Stage Condensing Gas Furnace
Sizes 060 thru 120
Utilizing the extensive resources available to Bryant, a new stan-
dard of excellence has been achieved with the model 352AAV
Plus 90t
4-Way Multipoise Furnace.
TM
The model 352AAV is a unique 4-way multipoise condensing fur-
nace with features like no other product in its class. The 352AAV
builds on the many Bryant successes in the furnace industry and
establishes a new standard for all high-efficiency gas furnaces.
FEATURES
Perfect Heat™ — The Plus 90t™ combines two heating stages to
vary the amount of gas being used from low-heat to high-heat
stage. The low-stage operation allows longer running periods,
which helps maintain your most comfortable temperature, prevents
drafts, reduces noise, and enhances the air quality of your home.
During extreme cold, the high-heat stage will run to ensure that you
are still comfortable.
Primary Heat Exchanger & Secondary Heat Exchanger — The
primary heat exchanger is corrosion resistant and maintains a
proven track record for long-term reliability and high-efficiency
performance. The secondary heat exchanger is built with a
patented lamination process that bonds a corrosion-proof lining of
polypropylene to a heavy, galvanized steel shell. The unique
secondary clamshell design allows wider spacing between cells for
reduced air resistance through the furnace, reduced load on the
blower motor, and reduced need for cleaning.
Perfect Light™ Igniter — Bryant's unique SiN igniter is not only
physically robust but it is also electrically robust. It is capable of
Product Data
running at line voltage and does not require complex voltage
regulators as do other brands. This unique feature further enhances
the reliability of Bryant's 352AAV gas furnace and continues
Bryant's tradition of providing a reliable and durable product.
Fan On Plus™ — Improves comfort all year long by allowing you
to select the continuous fan speed right at the thermostat.
SmartEvap™ — Allows your system to reduce summertime
humidity levels by nearly 10% over standard systems.
Media Filter Cabinet — Enhanced indoor air quality in your home
is made easier with our media filter cabinet—a standard accessory
on all furnaces. When installed as a part of your system, this cabinet
allows for an easy and convenient addition of a Bryant high-
efficiency air filter.
Adaptive Logic Control Board — This self-adjusting control
board contains a microprocessor which automatically calculates
the precise amount of time your furnace should run and at what
speed it should run to obtain the best comfort and energy efficiency.
This control board also includes an extensive troubleshooting and
component test sequence that can monitor your heating system to
ensure that it is operating properly.
4-Way Multipoise Design — Allows the model 352AAV to be
installed in an upflow, downflow, or horizontal orientation. Factory
configured for upflow applications with only simple drain connection
changes required for conversion to downflow or horizontal.
A05085
Direct or Non-direct Venting — The 352AAV can be installed as
a Non-Direct 1-pipe vent or Direct 2-pipe vent furnace. This
provides added flexibility to meet diverse installation needs.
Full Cabinet Insulation — This insulation completely surrounds
the internal furnace casing allowing for reduced and dampened
sounds and maintained efficiencies.
Two-Speed Inducer Motor — This motor works with the inducer
fan to optimize combustion efficiency and exhaust the flue gases
out of the house. The motor has two speeds and an incorporated
fan to keep the motor cool while reducing sound.
Permanent Split Capacitor (PSC) Blower Motor
has a PSC blower motor that has several preselected fixed speeds
which can be customized to duct work installation requirements.
The motor has a wide application of use, a basic control scheme,
and is extremely reliable.
Soft Motor Mounts — These motor mounts help to absorb shock,
decrease the vibration of the motor, and minimize noise.
Two Stage Gas Valve —The 352AAV has a 2-stage gas valve to
vary the amount of gas being used from low-heat to high-heat
stage. The low-stage operation allows longer running periods,
which helps maintain your most comfortable temperature, prevents
drafts, reduces noise, and enhances the air quality of your home.
During the extreme cold, the high-heat levels will run to ensure that
you are still comfortable.
352AAV
— The

Advertisement

loading

Summary of Contents for Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV

  • Page 1 The model 352AAV is a unique 4-way multipoise condensing fur- nace with features like no other product in its class. The 352AAV builds on the many Bryant successes in the furnace industry and establishes a new standard for all high-efficiency gas furnaces.
  • Page 2 times times italic times bold —2—...
  • Page 3: Clearance To Combustibles

    Clearance to Combustibles This forced air furnace is equipped for use with natural gas at altitudes 0 - 10,000 ft (0 - 3,050m), except 140 size Furnaces are only approved for altitudes 0 - 7,000 ft. (0 - 2,135m). An accessory kit, supplied by the manufacturer, shall be used to convert to propane gas use or may be required for some natural gas applications.
  • Page 4: Specifications

    UNIT SIZE RATINGS AND PERFORMANCE Input Btuh† Output Capacity BTUH* (ICS) Direct Vent (2-Pipe) (Shaded capacities are specified on rating plate) Non-Direct Vent (1-Pipe) AFUE† Direct Vent (2-Pipe) Nonweatherized ICS Non-Direct Vent (1-Pipe) Certified Temperature Rise Range °F Certified External Static Pressure (ESP) (In.
  • Page 5: Concentric

    ‡‡ Length shown is measured 1 way along wire path between unit and service panel for maximum 2% voltage drop. *** Required for installation on combustible floors when no coil box is used, or when any coil box other than a Bryant CD5 or CK5 cased coil is used.
  • Page 6 COMBUSTION-AIR AND VENT PIPING FOR DIRECT VENT (2-PIPE) AND NON-DIRECT VENT (1-PIPE) APPLICATIONS DIRECT VENT (2-PIPE) ONLY UNIT MAX ALTITUDE (FT) INPUT RATE TERMINATION (BTUH) 2 Pipe or 2-in 60,000 Concentric 2 Pipe or 2-in 80,000 Concentric 0 to 2000 2 Pipe or 3-in 100,000 Concentric...
  • Page 7: Pipe Or 2-In

    COMBUSTION-AIR AND VENT PIPING FOR DIRECT VENT (2-PIPE) AND NON-DIRECT VENT (1-PIPE) APPLICATIONS continued MAXIMUM ALLOWABLE PIPE LENGTH (FT) (CONTINUED) DIRECT VENT (2-PIPE) ONLY UNIT MAX ALTITUDE (FT) INPUT RATE TERMINATION (BTUH) 2 Pipe or 2-in 60,000 2 Pipe or 2-in 80,000 4001 to 5000‡...
  • Page 8: Pipe) Only Pipe Dia 1

    3. Assume two 45° elbows equal one 90° elbow. Wide radius elbows are desirable and may be required in some cases. 4. Elbows and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count.
  • Page 9 MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT) WITH AND WITHOUT INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT * WINTER DESIGN TEMPERATURE UNIT SIZE (°F) –20 –20 –20 –20 –20 –20 –20 * Pipe length (ft) specified for maximum pipe lengths located in unconditioned spaces. Pipes located in unconditioned space cannot exceed total allowable pipe length as specified in Table 6.
  • Page 10: Condensate Trap

    FURNACE BLOWER SHELF DOOR CONDENSATE TRAP (INSIDE) FIELD DRAIN CONN ALTERNATE DRAIN TUBE LOCATION SIDE VIEW CONDENSATE TRAP DRAIN TUBE LOCATION DOWNFLOW AND ALTERNATE UPFLOW APPLICATIONS EXTERNAL UPFLOW APPLICATIONS SLOT FOR SCREW HORIZONTAL APPLICATION (OPTIONAL) WIRE TIE GUIDES (WHEN USED)
  • Page 11 ACCESSORY DOWNFLOW SUBBASE LOCATING LOCATING FURNACE CASING WIDTH FURNACE IN DOWNFLOW APPLICATION Furnace with or without Cased Coil 17-1/2 Assembly or KCAKC Coil Box Furnace with or without Cased Coil Assembly or KCAKC Coil Box Furnace with or without Cased Coil 24-1/2 Assembly or KCAKC Coil Box * The plenum should be constructed 1/4 in.
  • Page 12 • An airflow reduction of up to 7% may occur when using the factory-specified 4-5/16-inch wide, high efficiency media filter. • For best furnace efficiency when using the 4 5/16-inch wide media filter, adjust blower speed tap to near the mid-point of the rise range.
  • Page 13 AIRFLOW ELECTRONIC AIR CLEANER COMBUSTION AIR INLET (NON-DIRECT VENT/ 1-PIPE APPLICATION HUMIDIFIER A/C COIL VENT PIPE A/C COIL HUMIDIFIER FRONT OF FURNACE VENT COMBUSTION AIR (DIRECT VENT/ 2 PIPE APPLICATION AIRFLOW FRONT OF FURNACE —13— GAS-FIRED WATER HEATER A05064 OUTDOOR...
  • Page 14 COMBUSTION-AIR INLET (NON-DIRECT VENT/1-PIPE APPLICATION) VENT PIPE ELECTRONIC AIR CLEANER FRONT OF FURNACE FURNACE CONDENSATE DRAIN REFRIGERATION PIPING AIRFLOW COMBUSTION - AIR INLET (NON-DIRECT VENT/ 1-PIPE APPLICATION) REFRIGERATION PIPING AIR CONDITIONING COIL AIRFLOW FURNACE CONDENSATE COMBUSTION–AIR PIPE DIRECT VENT/2-PIPE APPLICATION)
  • Page 15 —15—...
  • Page 16 Casing Casing shall be of .030 in. thickness minimum, pre-painted gal- vanized steel. ©Bryant Heating & Cooling systems 7310 W. Morris St. Indianapolis, IN 46231 GUIDE SPECIFICATIONS Two Speed Inducer Motor Two Speed Inducer motor shall be soft mounted to reduce vibra- tion transmission.