Summary of Contents for South-Tek Systems BEERBLAST 7 KPH
Page 1
NOTE: SCHEMATICS and BROCHURES APPENDED BEERBLAST™ 7/14KPH & N2-GEN™ 7/14KPH O&M MANUAL Revision 1 Date 06/13/16 Copyrighted All Rights Reserved 2016...
Page 2
BeerBlast™ 7/14KPH & N -GEN™ 7/14KPH O&M South-Tek Systems VERSION HISTORY Revision Implemented Revision Approved Approval Reason Date Date James Nguyen 12/15/14 J. Nguyen 12/15/14 James Nguyen 6/13/16 J. Nguyen 6/13/16...
Page 3
BeerBlast™ 7/14KPH & N -GEN™ 7/14KPH O&M South-Tek Systems --------------------------------------------------------------------------Notes Page------------------------------------------------------------------------...
BeerBlast™ 7/14KPH & N -GEN™ 7/14KPH O&M South-Tek Systems TABLE OF CONTENTS 1 INTRODUCTION ................................6 Purpose................................6 Audience ................................6 Important Information ............................6 2 SAFETY GUIDELINES ..............................7 General ................................7 3 SYSTEM DESCRIPTION ..............................8 Key Features ..............................8 Specifications (BeerBlast™...
Page 5
BeerBlast™ 7/14KPH & N -GEN™ 7/14KPH O&M South-Tek Systems ----------------------------------------------------------------------------Notes------------------------------------------------------------------------------...
BeerBlast™ 7/14KPH & N -GEN™ 7/14KPH O&M South-Tek Systems INTRODUCTION PURPOSE The BeerBlast™ 7/14KPH / N -GEN™ 7/14KPH provide an economical, precise means of supplying mixed beer gas to “push” the beer to the tap within restaurant and bar establishments. Beer brewers have established...
BeerBlast™ 7/14KPH & N -GEN™ 7/14KPH O&M South-Tek Systems SAFETY GUIDELINES GENERAL Correct use of the BeerBlast™ 7/14KPH / N -GEN™ 7/14KPH is important for your personal safety and for trouble- free functioning of the BeerBlast™ 7/14KPH / N -GEN™ 7/14KPH. Incorrect use can cause damage to the BeerBlast™...
BeerBlast™ 7/14KPH & N -GEN™ 7/14KPH O&M South-Tek Systems SYSTEM DESCRIPTION KEY FEATURES The BeerBlast™ 7KPH and 14KPH / N -GEN™ 7KPH and 14KPH key features include the following: Air compressor Air Filters Programmable Logic Controller (PLC) Pressure Swing Adsorption Beds...
BeerBlast™ 7/14KPH & N -GEN™ 7/14KPH O&M South-Tek Systems SYSTEM OPERATIONS The system has three standard run modes – Run, Cool, and Standby. When the power switch is turned on, the controller will automatically determine which mode to enter and will display the current run mode on the screen –...
Identify and verify that all parts listed on the packing list are present and undamaged. South-Tek Systems (STS) is not responsible for damages that have occurred during the shipping and handling of the BeerBlast™ 7KPH / N -GEN™...
Identify and verify that all parts listed on the packing list are present and undamaged. South-Tek Systems (STS) is not responsible for damages that have occurred during the shipping and handling of the BeerBlast™ 14KPH / N -GEN™...
BeerBlast™ 7/14KPH & N -GEN™ 7/14KPH O&M South-Tek Systems ELECTRICAL REQUIREMENTS The BeerBlast™ 7/14KPH / N -GEN™ 7/14KPH requires 110–220V / 50-60 hz / 1ph connection. It has a built in 20A circuit breaker and a standard 3-prong US power cord is provided for the electrical connection. The system is UL 508A ICP approved.
Page 14
BeerBlast™ 7/14KPH & N -GEN™ 7/14KPH O&M South-Tek Systems Item STS Part # Description BB™ 7KPH Mini PSA 800-133 S-100/200 12" Mounting Bracket 800-134-B S-100/200/400 18" Mounting Bracket 800-129 Type 1 Lower Wall Mount Bracket Misc 0.250" -20 x 0.750" Carriage Bolt Misc 0.250"...
BeerBlast™ 7/14KPH & N -GEN™ 7/14KPH O&M South-Tek Systems INSTALLATION (BEERBLAST™ 7KPH / N -GEN™ 7KPH) The BeerBlast™ 7KPH / N -GEN™ 7KPH Mixed Gas Dispense System can be installed for one or multiple CO blends. It is necessary to use caution when working with pressurized gas, making sure that all fittings and gas lines are installed correctly.
BeerBlast™ 7/14KPH & N -GEN™ 7/14KPH O&M South-Tek Systems GAS CONNECTION (BEERBLAST™ 7KPH / N -GEN™ 7KPH) See figures below for panel layout and gas connections. Double-check all connection locations before turning on the system or opening any valves. Note: All BeerBlast™ 7KPH N -GEN™...
Page 19
BeerBlast™ 7/14KPH & N -GEN™ 7/14KPH O&M South-Tek Systems Figure 1: 100# N2 Storage Tank Setup...
BeerBlast™ 7/14KPH & N -GEN™ 7/14KPH O&M South-Tek Systems INSTALLATION (BEERBLAST™ 14KPH / N -GEN™ 14KPH) The BeerBlast™ 14KPH / N -GEN™ 14KPH needs to be installed on a hard flat surface capable of supporting 300+ lbs. There are (4) anchor bolt holes on the support legs that can be used to secure the unit to the floor. It is not required to be anchored, but always follow any site/local codes regarding securing equipment.
Page 21
BeerBlast™ 7/14KPH & N -GEN™ 7/14KPH O&M South-Tek Systems Once the connections are all secure, turn on the power (switch is located externally on the upper left side of the cabinet on the control panel). The initial start-up will require up to 1 hour to fully pressurize the internal storage tank to the correct level.
BeerBlast™ 7/14KPH & N -GEN™ 7/14KPH O&M South-Tek Systems NITROGEN CYLINDER BACK-UP (BEERBLAST™ 7/14KPH / N -GEN™ 7/14KPH) It is recommended that a backup system be installed in case of any unforeseen complications. A backup N Cylinder tank can be used instead of the generated nitrogen from the BeerBlast™ 7/14KPH / N -GEN™...
C. If there is a leak within the unit, remove the cover and locate the issue. If you have to replace any parts, only use factory parts supplied from your distributor or South-Tek Systems. Consult the factory if there are any questions.
BeerBlast™ 7/14KPH & N -GEN™ 7/14KPH O&M South-Tek Systems 4.11 ACCESS CONTROLS The built in controller is fully programmed to function without requiring the user to input any values. Do not attempt to modify the program or the warranty will be voided. In case of the program failure, first attempt to cycle the power to the system.
BeerBlast™ 7/14KPH & N -GEN™ 7/14KPH O&M South-Tek Systems SYSTEM USAGE INSTRUCTIONS The BeerBlast™ 7/14KPH / N -GEN™ 7/14KPH is intended to be used to generate Nitrogen, and provide a CO blend to push beer out of the keg. Follow the installation instructions above and only use in an approved environment.
BeerBlast™ 7/14KPH & N -GEN™ 7/14KPH O&M South-Tek Systems SYSTEM MAINTENANCE Whenever doing any maintenance to the system, make sure to power down the system. Remove the front cover to gain access to the filters. Annual Filter replacement kit part # FRP-001 Air Pre-Filter The integrated Air Compressor has an air intake pre-filter.
Page 27
BeerBlast™ 7/14KPH & N -GEN™ 7/14KPH O&M South-Tek Systems Particulate and Coalescing Filter The particulate and coalescing filter after the air compressor is designed to capture particulate and moisture prior to entering the rest of the system. These filters need to be replaced once per year or every 1000 hours, whichever comes first.
BeerBlast™ 7/14KPH & N -GEN™ 7/14KPH O&M South-Tek Systems KEY CONTACTS Contact your local provider/installer for any questions with the performance and/or maintenance of the system. They will be best suited to answer your questions and your quickest solution on any issues you may have.
BeerBlast™ 7/14KPH & N -GEN™ 7/14KPH O&M South-Tek Systems GAS LEAKS As with any gas system, only use a spray bottle on non-electrical equipment to find leaks. Fix or replace leaking fittings or old hose. Push-to-connect fittings will show bubbles and typically have up to a 5ccm acceptable leakage rate.
-GEN™ 7/14KPH System is warrantied against any defects in workmanship and materials for 12 months (or 1000 hours) from the date of shipment from South-Tek Systems, whichever comes first. The purchaser has the liability to ensure that the system is fully inspected upon delivery and shall contact the appropriate shipping company to make any claims on damaged goods due to transit within that shipping company’s...
Page 31
BeerBlast™ 7/14KPH & N -GEN™ 7/14KPH O&M South-Tek Systems ------------------------------------------------------------------------Last Page--------------------------------------------------------------------------...
Page 32
THE INFORMATION CONTAINED IN THIS DRAWING IS NUMBER: REVISION: Refer to Drawing A01-BB-01 for 800-111-L, A01-0100-S, GA-TYP1P-NP07KPH THE SOLE PROPERTY OF SOUTH-TEK SYSTEMS. A01-0100-S Tank Manifold ANY REPRODUCTION IN PART OR AS A WHOLE and A01-0100-A for Tank Assembly Design Data.
Page 33
2 of 2 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS NUMBER: REVISION: GA-TYP1P-NP07KPH THE SOLE PROPERTY OF SOUTH-TEK SYSTEMS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SOUTH- TEK SYSTEMS IS PROHIBITED.
Page 34
1 of 1 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS NUMBER: REVISION: DD-NP-07KPH THE SOLE PROPERTY OF SOUTH-TEK SYSTEMS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SOUTH- TEK SYSTEMS IS PROHIBITED.
Page 35
REVISION: 1) All Connections are 1/4" NPT unless otherwise specified. DD-A01-BB-01 THE SOLE PROPERTY OF SOUTH-TEK SYSTEMS. ANY REPRODUCTION IN PART OR AS A WHOLE 2) Tank should be set on a hard stable surface. WITHOUT THE WRITTEN PERMISSION OF SOUTH-...
Page 36
ITEM # STS PART # DESCRIPTION QTY. TYP1 Unit TYP1P Unit Shown 800-133 S-100/200 Mounting Bracket 800-134-B S-100/200/400 18" Mounting Bracket 800-129 100/200 Lower Wall Mount Bracket 002-382 .250"-20 x 0.750" HHCS Reference 0.250" -20 x 0.750" Carriage Bolt Reference 0.250" Flat Washer Reference 0.250"...
Page 37
Refer to Drawing A01-BB-01 for 800-111-L, A01-0100-S, THE INFORMATION CONTAINED IN THIS DRAWING IS NUMBER: REVISION: GA-TYP1P-BP07KPH THE SOLE PROPERTY OF SOUTH-TEK SYSTEMS. A01-0100-S Tank Manifold and A01-0100-A for Tank Assembly Design Data. ANY REPRODUCTION IN PART OR AS A WHOLE...
Page 38
2 of 2 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS NUMBER: REVISION: GA-TYP1P-BP07KPH THE SOLE PROPERTY OF SOUTH-TEK SYSTEMS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SOUTH- TEK SYSTEMS IS PROHIBITED.
Page 39
1 of 1 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS NUMBER: REVISION: DD-BB-07KPH THE SOLE PROPERTY OF SOUTH-TEK SYSTEMS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SOUTH- TEK SYSTEMS IS PROHIBITED.
Page 40
REVISION: 1) All Connections are 1/4" NPT unless otherwise specified. DD-A01-BB-01 THE SOLE PROPERTY OF SOUTH-TEK SYSTEMS. ANY REPRODUCTION IN PART OR AS A WHOLE 2) Tank should be set on a hard stable surface. WITHOUT THE WRITTEN PERMISSION OF SOUTH-...
Page 41
ITEM # STS PART # DESCRIPTION QTY. TYP1 Unit TYP1P Unit Shown 800-133 S-100/200 Mounting Bracket 800-134-B S-100/200/400 18" Mounting Bracket 800-129 100/200 Lower Wall Mount Bracket 002-382 .250"-20 x 0.750" HHCS Reference 0.250" -20 x 0.750" Carriage Bolt Reference 0.250" Flat Washer Reference 0.250"...
Page 42
THE INFORMATION CONTAINED IN THIS DRAWING IS NUMBER: REVISION: -2.5" If Bypass is Active ES-TYP1P THE SOLE PROPERTY OF SOUTH-TEK SYSTEMS. 11-12 are Open ANY REPRODUCTION IN PART OR AS A WHOLE TB-4C 11-14 are Closed Brown *Pressure Switch See Notes 1-3* 15"...
Page 43
BlastOff - Leak Detection System ™ Provided Exclusively with the BeerBlast - Mixed Gas Dispense System ® MAXIMIZE THE LIFE OF YOUR NITROGEN GENERATION SYSTEM...! South-Tek developed the Patented BlastOff - Leak Detection System to ™ proactively ensure the longevity of not only the draft beer system, but also the Nitrogen Generation System itself.
Page 44
- Mixed Gas Dispense System BeerBlast ® all-new 2017 Introducing South-Tek’s BeerBlast ® Mixed Gas Dispense System that redefines nitrogen generation technology for draft beer applications. Engineered for greater longevity and higher output, the new BeerBlast provides the exact ® blend of CO and Nitrogen, protecting the kegged product quality and ultimately increasing profitability and customer satisfaction.
Page 45
85 lbs 275 lbs Generator *Calculations will vary based on keg pressure and the CO2/Nitrogen blend Distributed by: South-Tek Systems, the Leading Designer and Manufacturer of Nitrogen Generation Technology BeerBlast - Mixed Gas Dispense System We ARE Nitrogen ® ™...