South-Tek Systems N2Blast FPS-1750 Manual

South-Tek Systems N2Blast FPS-1750 Manual

Fire protection systems

Advertisement

FPS-1750
FPS-3000
FPS-6000
Fire Protection Systems
O&M Manual
Version 7; 05/24/2016
© 2020
The Leader in Nitrogen Generation Technology

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the N2Blast FPS-1750 and is the answer not in the manual?

Questions and answers

Summary of Contents for South-Tek Systems N2Blast FPS-1750

  • Page 1 FPS-1750 FPS-3000 FPS-6000 Fire Protection Systems O&M Manual Version 7; 05/24/2016 © 2020 The Leader in Nitrogen Generation Technology...
  • Page 2 ® -BLAST Nitrogen Generator FPS-1750, FPS-3000, and FPS-6000 South-Tek Systems VERSION HISTORY Revision Implemented Revision Approved Approval Reason Date Date J. Nguyen 10/13/13 A. Norman 10/13/13 Initial Release J. Nguyen 7/5/14 A. Norman 7/5/14 J. Nguyen 8/15/14 A. Norman 8/15/14 J.
  • Page 3: Table Of Contents

    ® -BLAST Nitrogen Generator FPS-1750, FPS-3000, and FPS-6000 South-Tek Systems TABLE OF CONTENTS 1 INTRODUCTION ........................6 Purpose ........................6 Audience ........................6 Important Information ....................6 2 SAFETY GUIDELINES ......................7 General ........................7 Service ........................7 3 SYSTEM DESCRIPTION ...................... 8 Key Features ......................
  • Page 4 ® -BLAST Nitrogen Generator FPS-1750, FPS-3000, and FPS-6000 South-Tek Systems APPENDIX D: INSTALLATION DIAGRAM ................ 23 APPENDIX E: APS INSTALLATION DIAGRAM ..............24 Version: 7 Revision Date: 5/24/16 Page 4 of 25...
  • Page 5 ® -BLAST Nitrogen Generator FPS-1750, FPS-3000, and FPS-6000 South-Tek Systems --------------------------------------------------Notes--------------------------------------------------- Version: 7 Revision Date: 5/24/16 Page 5 of 25...
  • Page 6: Introduction

    ® -BLAST Nitrogen Generator FPS-1750, FPS-3000, and FPS-6000 South-Tek Systems 1 INTRODUCTION PURPOSE ® The N -BLAST Nitrogen Generator FPS-1750, FPS-3000, and FPS-6000 (Type II Series), provide an economical, precise means of generating high purity nitrogen. Since air is comprised of ~79% N we simply and cost-effectively separate the N from the air.
  • Page 7: Safety Guidelines

    ® -BLAST Nitrogen Generator FPS-1750, FPS-3000, and FPS-6000 South-Tek Systems 2 SAFETY GUIDELINES GENERAL ® Correct use of N -BLAST Nitrogen Generator is important for your personal ® safety and for trouble-free functioning of the N -BLAST Nitrogen Generator. ®...
  • Page 8: System Description

    ® -BLAST Nitrogen Generator FPS-1750, FPS-3000, and FPS-6000 South-Tek Systems 3 SYSTEM DESCRIPTION KEY FEATURES ® The N -BLAST Nitrogen Generator key features include the following: Air Filters and Pressure Regulator Membrane Pressure Switch for Automatic Start/Stop (per demand) Safety Relief Valve...
  • Page 9: Specifications

    ® -BLAST Nitrogen Generator FPS-1750, FPS-3000, and FPS-6000 South-Tek Systems SPECIFICATIONS Table 1: Specification Data ® -BLAST Nitrogen Generator FPS-1750, FPS-3000 & FPS-6000 Specifications Nitrogen Purity 98.0+% Installation Wall Mounted Display Hours / Operating / Standby / BlastOff N₂ Storage Pressure...
  • Page 10: Product Installation

    Identify and verify that all parts listed on the packing list are present and undamaged. South-Tek Systems (STS) is not responsible for damages that have ® occurred during the shipping and handling of the N -BLAST Nitrogen Generator.
  • Page 11 ® -BLAST Nitrogen Generator FPS-1750, FPS-3000, and FPS-6000 South-Tek Systems Figure 1: N2-Blast® Type II Series Wall Mount Diagram ® 1. Install the lower mounting bracket on the N -BLAST Nitrogen Generator by sliding the bracket through the keyway on the lower mounting flanges. (Item #3 into Item #4) a.
  • Page 12: Installation (For Nitrogen -Blast Nitrogenitrogen Generator)

    ® -BLAST Nitrogen Generator FPS-1750, FPS-3000, and FPS-6000 South-Tek Systems 4. An 110VAC power connection should be installed per local code by a qualified electrician. See the wiring diagram for specifics. Optionally a standard 110VAC power cord can be installed on the system by a qualified electrician.
  • Page 13: Panel Layout And Gas Connection

    ® -BLAST Nitrogen Generator FPS-1750, FPS-3000, and FPS-6000 South-Tek Systems adjustment is required. PANEL LAYOUT AND GAS CONNECTION Air Input is located on the left side of the unit. Nitrogen outlet will be located on the right side of the unit. Double-check all connection locations before turning on the system or opening any valves.
  • Page 14: System Usage

    ® -BLAST Nitrogen Generator FPS-1750, FPS-3000, and FPS-6000 South-Tek Systems 5 SYSTEM USAGE INSTRUCTIONS ® The N -BLAST Nitrogen Generator is intended to be used to generate nitrogen and provide nitrogen for the fire protection piping system. Follow the installation instructions above and only use in an approved environment.
  • Page 15 ® -BLAST Nitrogen Generator FPS-1750, FPS-3000, and FPS-6000 South-Tek Systems the pipe lines, loose fittings, faulty connection, etc. These leaks are potential safety hazards, they can cause the nitrogen to deplete quickly, and could cause your N ® BLAST Nitrogen Generator to run in excess (decreasing the life of the unit).
  • Page 16: System Maintenance

    Filter Replacement Kits can be purchased from South-Tek Systems that include the Filter Elements for the specified unit (STS Part # FRP-002). Prior to Filter Bowl Removal Ensure the power has been disconnected from the source.
  • Page 17 ® -BLAST Nitrogen Generator FPS-1750, FPS-3000, and FPS-6000 South-Tek Systems secure it in place with the threaded ring. 4) Before reinstallation of the filter bowl, be sure to clean out any debris with hot water and shake dry the water out.
  • Page 18: Key Contacts

    ® -BLAST Nitrogen Generator FPS-1750, FPS-3000, and FPS-6000 South-Tek Systems 6) To reinstall the filter bowl, reverse the procedures used in removing the filter bowl. ® Reconnecting Your N -BLAST Nitrogen Generator: 1) After all filter elements have been replaced, wipe down all surfaces with a clean dry towel.
  • Page 19: Gas Leaks

    ® -BLAST Nitrogen Generator FPS-1750, FPS-3000, and FPS-6000 South-Tek Systems GAS LEAKS: As with any gas system, only use a spray bottle on non-electrical equipment to find leaks. Fix or replace leaking fittings or old hose. Push-to-connect fittings will show bubbles and typically have up to a 5ccm acceptable leakage rate.
  • Page 20: Appendix A: Warranty

    RMA number (return authorization number) may be denied and returned to the sender. Contact the factory for RMA #’s, prior to return shipment. South-Tek Systems is not liable for damages caused by normal wear and tear, water, fire, erosion, corrosion, explosion, misuse, oil/gas vapors or unauthorized modifications.
  • Page 21: Appendix B: Auto Purge System (Aps)

    ® -BLAST Nitrogen Generator FPS-1750, FPS-3000, and FPS-6000 South-Tek Systems APPENDIX B: AUTO PURGE SYSTEM (APS) Installation and Quick Start Guide Auto Purge Assembly Settings Label Flow Setting Indicator Introduction to APS: The AutoPurge System™ is simple to install and requires little maintenance. This device...
  • Page 22: Appendix C: Wiring Diagram

    ® -BLAST Nitrogen Generator FPS-1750, FPS-3000, and FPS-6000 South-Tek Systems APPENDIX C: WIRING DIAGRAM Version: 7 Revision Date: 5/24/16 Page 22 of 25...
  • Page 23 ® -BLAST Nitrogen Generator FPS-1750, FPS-3000, and FPS-6000 South-Tek Systems APPENDIX D: INSTALLATION DIAGRAM Version: 7 Revision Date: 5/24/16 Page 23 of 25...
  • Page 24 ® -BLAST Nitrogen Generator FPS-1750, FPS-3000, and FPS-6000 South-Tek Systems APPENDIX E: APS INSTALLATION DIAGRAM Version: 7 Revision Date: 5/24/16 Page 24 of 25...
  • Page 25 ® -BLAST Nitrogen Generator FPS-1750, FPS-3000, and FPS-6000 South-Tek Systems -------------------------------------------------Last Page------------------------------------------------- Version: 7 Revision Date: 5/24/16 Page 25 of 25...

This manual is also suitable for:

N2blast fps-3000N2blast fps-6000

Table of Contents