High-efficiency automatic backwash disk prefilter (9 pages)
Summary of Contents for Runxin RL-R50
Page 1
Residential Softener RL-R50 RL-R60 RL-R80 RL-R100 RL-R110 RL-R120 RL-R150 Pictures for reference subject to real products. User Manual Please read this manual in details before using the product and keep it properly in order to consult in the future 0WRX.466.584...
Page 2
Catalogue Preface 1. Product Profile ........................2. Working Principle ....................... 3. Assembly & Parts ....................... 4. Function and Characteristics ..................... 5. Application ......................... 6. Technical Parameters ......................7. Setting and Usage ..........................7.1 Control Valve Setting and Usage……………………………………………………………… ※The Function of Control Panel and Parameter Setting............※Parameter Setting.......................
Preface Thanks for choosing our softener series products. These products are featured by good softening effects, stable performance, excellent appearance, compact structure and simple handling, etc. They can meet the soften water demand of family washing, bathing, cleaning and boiling, etc. Besides, they also can be applied to supplying high quality soften water for institutions, schools, group companies, and so on.
●Split type structure (For example D type) 4. Function and Characteristics 1. Regeneration starts automatically: According to the regeneration time and water treatment capacity of one cycle, the system will start the regeneration program. 2. Hardness of raw water can be set: After inputting the hardness value, the control valve will...
Page 5
automatically calculate the system water treatment capacity and display on the LCD screen. 3. Water hardness can be adjusted: It can adjust the hardness of outlet water by adjusting the bypass. 4. Automatic memory function: The parameters set by users, such as regeneration time, backwash time, brine &...
Model Dimension Drain Rate(L/h) (L/h) Per Cycle Water Volume (L) Size(in) (Φ×h) mm (L) Quantity (m 300~500 180×331 0713 500~800 180×432 0717 RL-R50 1200 500~800 0815 205×381 RL-R60 500~1000 1800 205×432 0817 RL-R80 800~1000 2500 232×432 0917 800~1200 1017 1/2”...
Page 7
7. Setting and Usage 7.1. Control Valve Setting and Usage ※The Function of Control Panel and Parameter Setting Button lock indicator Light on, indicating the buttons are locked. At this moment, press any single button will not work (No operation in one minute, will light on and lock the buttons.) Solution:Press and hold both for 5 seconds until the...
Page 8
※Parameter Setting Meter Type Softener Valve Parameter Setting Time of Day Time of Day 12:12 Regeneration Time Regeneration Time 02:00 Water Hardness Water Hardness 150mg/L Parameter Set Factory Item Actual Value Arrange Default Current Time of Day 00:00~23:59 time Regeneration Time 00:00~23:59 02:00 Water Hardness...
Page 9
and enter into the interface of “Set Softener 1.Press Set Softener Para. Para.”, as the figure LR1 shows. Set Time of Day twice and select the item of “ Set Water 2 . Press Set Regen. Time Hardness ”; then press , the setting interface will display as 》Set Water Hardness the figure LR4;...
Page 10
03:25:50 Water System Motor Running… Fast Rinsing… Remaining: 5 min. Fast Rinse Status Motor Running ●The working process is Service→ Backwash→ Brine& Slow Rinse→ Brine Refill →Fast Rinse→ Service (Cycle repeats). 7.2. The Installation and Usage of Brine Valve The brine valve plays two roles in the whole system: First, under the brine and slow rinse status, with the floating ball, the brine valve can prevent the air from being inhaled which may affected the regeneration and usability.
8. Usage Illustration After installing the device and setting the relevant parameters, please conduct the trial running as follows: ※Fill the brine tank with the planned regeneration salt and the water(Refer to the below table), making the brine is saturated (26%). Then start the device (This step is necessary only for the situation that the device is put into use for the first time.) Resin Tank 0713...
Page 12
salt. When the level controller reaches the required height, the refilling will be stopped. The new saturated brine will be used for next regeneration. 03:15:50 Water System Brine Refilling… Remaining: 05:30 min.:s. Brine Refill Status ※Press and turn into Fast Rinse status, starting to Fast Rinse. About 3 minutes fast rinse will discharge the residual brine and compact the resin particle so as to reach the best softening effect.
Page 13
9. Notice Before reading and understanding the user manual, please do not operate the device. ※Before installation and trial test the product, please take out the spare parts kit and filling material from the cabinet(See the below picture). ※To ensure normal operation of the product after installed, please consult with professional installation or repairing personnel before use it.
Page 14
※Please strictly use the salt of more than 99% purity only. Any salt with additive or large particles is forbidden to add. ※Please use this product under the water temperature between 5~45℃,water pressure 0.15~ 0.6MPa. Failure to use this product under such conditions voids the warranty. ※Sodium used in the water softening process should be considered as part of your overall dietary salt intake.
reset the time. ※For safety usage, the overflow connector should be installed in the product. ※Check the softener regularly, checking item: a)If there is any pipeline leakage. If it does, contact with your seller. b)If the overflow connector blocked, if it does, clean it. c)If the brine well in vertical.
Page 16
※ It couldn’t be repaired free of charge under the below conditions: Resin, seal, decoration shell, the coating of appearance, etc. The damage is caused by force majeure, such as fire, flood, electric shock, earthquake, etc. The damage is result from the disassembly or refits by user or repair by non-scheduled maintenance unit.