Notes for operators and responsible maintenance personnel
★ Please read through this Instruction Manual as well as the separate Instruction
Manual "Safety (MN1-6105)" and "Cleaning, Disinfection and Sterilization
(MN1-6117)" carefully prior to use.
★ Keep this Instruction Manual together with the ultrasound diagnostic instru-
ment for any future reference.
© Hitachi, Ltd. 2015, 2017. All rights reserved.
S3ESL1 Probe
Instruction Manual
Specification
MN1-6111 Rev.4
i
MN1-6111 Rev.4

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi S3ESL1

  • Page 1 ★ Please read through this Instruction Manual as well as the separate Instruction Manual “Safety (MN1-6105)” and “Cleaning, Disinfection and Sterilization (MN1-6117)“ carefully prior to use. ★ Keep this Instruction Manual together with the ultrasound diagnostic instru- ment for any future reference. © Hitachi, Ltd. 2015, 2017. All rights reserved.
  • Page 2 MN1-6111 Rev.4...
  • Page 3 MN1-6111 Rev.4 Introduction This is the instruction manual for S3ESL1 probe. The probe is available by connecting to Hitachi’s ultrasound diagnostic instrument and can be mainly used for observations of the heart. Prior to use, read this manual as well as the separate instruction manual “Safety” in which information for safe use is provided.
  • Page 4: Table Of Contents

    MN1-6111 Rev.4 CONTENTS 1. General Information ...........................1 1-1. Intended use ...................................1 1-2. Classification of ME equipment ............................1 1-3. Standard components ..............................1 1-4. Options ..................................1 2. Specifications and Parts name ........................3 2-1. Specifications .................................3 2-2. Specifications of the bite block .............................4 2-3.
  • Page 5: General Information

    • Method of sterilization ..................Refer to the separate instruction manual “Cleaning, Disinfection and Sterilization” 1-3. Standard components The standard components of S3ESL1 probe are as follows. S3ESL1 Probe ························································ 1 set Bite block SP-7901 ··················································· 2 set Storage case ··························································· 1 set Instruction Manual •...
  • Page 6 MN1-6111 Rev.4...
  • Page 7: Specifications And Parts Name

    At the time of publication of this manual, the connectable diagnostic ultrasound instrument or instrument software version available with this probe is different for each country, please refer to the instrument instruction manual or contact your local Hitachi representative. Field of view: 90°...
  • Page 8: Specifications Of The Bite Block

    MN1-6111 Rev.4 2-2.Specifications of the bite block Material Polyetherimide Service life Three years External dimensions As shown in the figure below. Unit: mm Remarks: The tolerance for the dimensions is ±10%. Figure 3 External view of the bite block 2-3. Transducer cover Use by covering the transducer cover over the insertion portion.
  • Page 9: Name Of Each Parts

    MN1-6111 Rev.4 2-4. Name of each parts The name of each part is shown in Figure 4 and the explanation for each part is listed in Table 2. Cable Lock lever Ring Angle knob for U/D Connector defrection Angle knob for TD rotation Proximal head Insertion portion...
  • Page 10 MN1-6111 Rev.4 Table 2 Name of each part and its explanation Name Explanation Ultrasound is radiated from this part. The electronic Ultrasonic radiation part Sector transducer is integrated underneath this part. Operating the angle knob allows this part to be bent UP/ Deflection portion DOWN direction The probe is inserted into the patient's body up to this...
  • Page 11: Preparations Before Use

    MN1-6111 Rev.4 3. Preparations before use This chapter describes preparations needed to use the probe safely. Please prepare the probe prior to each use by following the instructions below. 3-1. Visual check Visually and tactually make certain that any of the following abnormalities has not taken place: Insertion portion is free from holes, dents, scratches, cracks, deformations, color changes and the like on the surface.
  • Page 12 MN1-6111 Rev.4...
  • Page 13: Operation

    Warning Use the transducer cover over the insertion portion as necessary . Use Hitachi-approved transducer cover . Use Hitachi-approved transducer cover only. If use transducer cover which not reccomended can cause an adverse reaction by the body of the patient..
  • Page 14: Insertion Of Probe

    MN1-6111 Rev.4 4-3. Insertion of Probe Insert the probe from bite block. Warning Do not try to forcibly perform operations. Excessive force cause injury to the patient. If an abnormal resistance force is felt, stop use of the equipment. Operation must be performed by a skilled doctor. Improper operation can injure the patient.
  • Page 15: Manipulation Of Probe

    MN1-6111 Rev.4 4-4. Manipulation of Probe An image of the region of interest is displayed on the monitor of the ultrasound diagnostic instrument. For details on displaying and adjusting the image, refer to the documentation supplied with the ultrasound diagnostic instrument. Warning If the probe gets bent in the esophageal (J turn), do not try to move the probe by force.
  • Page 16 MN1-6111 Rev.4 Caution Constantly check for anything abnormal about the patient’s condition and the equipment. Continued use without noticing that an abnormal condition has occurred can result in an electric shock and injury to the operator or patient. If an abnormal condition occurs, immediately move the equipment away from the patient and stop use of the probe.
  • Page 17: Manipulation Of The Deflection Portion

    MN1-6111 Rev.4 4-5. Manipulation of the deflection portion After inserting the insertion portion into the patient’ s esophagus, flex the tube as indicated below in order to observe the target region. DOWN Turn the angle knob to U direction (represented by an arrow) to bend the deflection portion in the ultrasound irradiation area side.
  • Page 18: Manipulation Of The Lock Lever

    MN1-6111 Rev.4 4-7. Manipulation of the lock lever The mechanism of deflection portion is fixed following figure as necessary. (1) Lock of angle knob Turn the lock lever to fix an angle of the diflection portion and opposite direction to free. Figure 9 4-8.
  • Page 19 MN1-6111 Rev.4 -15-...
  • Page 20 +81-3-6284-3668 http://www.hitachi.com/businesses/healthcare/index.html Overseas Offices: Hitachi Medical Systems GmbH Otto-von-Guericke-Ring 3 D-65205 Wiesbaden, Germany EU Importer: Hitachi Medical Systems Europe Holding AG Address: Sumpfstrasse 13 CH-6300 Zug, Switzerland US Importer: Hitachi Healthcare Americas Corporation Address: 1959 Summit Commerce Park, Twinsburg, Ohio 44087...