RUTHMAN RAE PUMPS MSVF Series Installation, Operation And Maintenance Manual

Multistage vertical external mount pumps

Advertisement

Quick Links

Installation,
Operation, and
Maintenance Manual
Multistage Vertical
External Mount Pumps
MSVF Series
60 Hz
MODELS
MSVF 1 MSVF 2
MSVF 3 MSVF 4
MSVF 8 MSVF16
MSVF 32 MSVF 42
MSVF 65 MSVF 85
RAE Pumps
1212 Streng Street
Cincinnati, OH 45223
513.779.3034
www.RAEPumps.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RAE PUMPS MSVF Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for RUTHMAN RAE PUMPS MSVF Series

  • Page 1 Installation, Operation, and Maintenance Manual MSVF Series Multistage Vertical External Mount Pumps 60 Hz MODELS MSVF 1 MSVF 2 MSVF 3 MSVF 4 MSVF 8 MSVF16 MSVF 32 MSVF 42 MSVF 65 MSVF 85 RAE Pumps 1212 Streng Street Cincinnati, OH 45223 513.779.3034 www.RAEPumps.com...
  • Page 2: Table Of Contents

    Table of Contents INTRODUCTION ..........................03 SPECIFICATIONS–SECTION A ....................03 MODEL CODE EXPLANATION ..................03 OPERATING PARAMETERS ..................... 04 MOTOR DATA ........................04 INSTALLATION–SECTION B ......................04 HANDLING .......................... 04 REQUIREMENTS ....................... 05 ELECTRICAL CONNECTION–SECTION C .................. 05 SPECIFICATIONS ......................05 CONNECTION ........................
  • Page 3: Introduction

    INTRODUCTION This Installation, Operation, and Maintenance Manual is designed to help you get the best performance and longest life from your RAE pump. This pump is a MSVF Series vertical multistage external mount pump. This pump should be securely mounted and not immersed during operation. This pump must be primed before operation. MSVF Series pumps are intended for industrial use to carry fluids such as water, coolant, light oil and other clean, non-aggressive liquids.
  • Page 4: Operating Parameters

    OPERATING PARAMETERS Ambient temperature: Max 104°F Liquid temperature range: 5°F to 158°F MSVF 1 MSVF 2 MSVF 3 MSVF 4 MSVF 8 Flow (gpm): 3 to 9 4 to 20 7 to 22 11 to 35 30 to 61 Head (feet): 57 to 689 85 to 768 57 to 712...
  • Page 5: Requirements

    REQUIREMENTS impurities, a strainer should be installed 1.5’ to 3’ in front of the inlet (particularly 1. The pump should be located in a well- recommended for pumps with flows less ventilated but frost-free area. than 35 gpm). 2. The distance between pump-motor and 9.
  • Page 6: Wiring Diagram

    the motor casing and connecting box subassembly together to proper position. Finally, screw the frame bolts tight, and put the WIRING DIAGRAM fan cover back. Figure 4 OPERATION AND MAINTENANCE–SECTION D 3. The pump has been filled with liquid as described in the START UP instructions ! WARNING ! below.
  • Page 7: Shutdown

    SEAL MAINTENANCE ! CAUTION ! Mechanical seal will be adjusted Do not start the pump until it has been automatically. The rotating and stationary fully filled with liquid and air vented. parts are lubricated and cooled by the transferring liquid. Ensure air vent screw hole is fully When replacing the mechanical seal, the tightened.
  • Page 8: Troubleshooting-Section E

    TROUBLE SHOOTING–SECTION E ! WARNING ! Verify electrical supply has been switched off before trouble shooting. Fault Possible Causes Possible Solutions Motor does not 1. No electrical supply 1. Check power supply start 2. Fuses blown or breaker tripped 2. Replace fuses 3.
  • Page 9: Dimensions-Section F

    DIMENSIONS AND WEIGHT–SECTION F MSVF1 Max Inlet Weight Pressure Model (inches) (inches) (inches) (inches) (inches) (pounds) (psi) MSVF1-20 19.02 10.16 8.86 5.83 4.61 44.09 MSVF1-30 19.73 10.87 8.86 5.83 4.61 44.09 MSVF1-40 20.43 11.57 8.86 5.83 4.61 46.30 MSVF1-50 21.14 12.28 8.86 5.83...
  • Page 10: Msvf 3 Dimensions, Weights And Outline Drawing

    MSVF3 Max Inlet Weight Pressure Model (inches) (inches) (inches) (inches) (inches) (pounds) (psi) MSVF3-20 19.02 10.16 8.86 5.83 4.61 44.09 MSVF3-30 19.73 10.87 8.86 5.83 4.61 46.30 MSVF1-40 20.43 11.57 8.86 5.83 4.61 48.50 MSVF3-50 22.32 12.68 9.65 6.69 5.59 55.12 MSVF3-60 23.03...
  • Page 11: Msvf 8 Dimensions, Weights And Outline Drawing

    MSVF8 Max Inlet Weight Pressure Model (inches) (inches) (inches) (inches) (inches) (pounds) (psi) MSVF8-20/1 23.30 13.66 9.65 6.69 5.59 70.55 MSVF8-20 25.40 14.06 11.41 7.48 6.10 83.78 MSVF8-30 26.65 15.24 11.41 7.48 6.10 90.39 MSVF8-40 30.39 16.81 13.58 7.76 6.50 108.02 MSVF8-50 21.57...
  • Page 12: Msvf 32 Dimensions, Weights And Outline Drawing

    MSVF32 Max Inlet Weight Pressure Model (inches) (inches) (inches) (inches) (inches) (pounds) (psi) MSVF32-10/1 33.46 19.88 13.58 7.75 6.50 160.94 MSVF32-10 33.85 19.88 13.98 9.06 7.40 178.57 MSVF32-20/2 37.99 22.64 15.35 10.23 8.19 209.44 MSVF32-20 37.99 22.64 15.35 10.23 8.19 222.67 MSVF32-30/2 40.75...
  • Page 13: Msvf 65 Dimensions, Weights And Outline Drawing

    MSVF65 Max Inlet Weight Pressure Model (inches) (inches) (inches) (inches) (inches) (pounds) (psi) MSVF65-10/1 37.44 22.09 15.37 10.23 8.19 240.30 MSVF65-10 46.10 26.41 16.69 12.99 10.04 390.21 MSVF65-20/2 49.37 29.69 16.69 12.99 10.04 412.26 MSVF65-20 52.32 29.69 22.64 14.17 11.22 546.75 MSVF65-30/2 55.55...
  • Page 14: Warranty-Section G

    WARRANTY–SECTION G RAE Pumps will replace, within one year of shipment from our plant, any pump that, in our judgment, has failed due to defects in materials or workmanship, provided the pump has been properly installed and maintained and has not been subject to abuse. Modifications, including removal of pump tags or misapplication, void this warranty.