INSTALLER OPTIONS CHART
Option
Description
Zone number
Range
1 to 8
01
Default
1
Home number
Range
1 to 32
02
Default
1
Program Control Module with Zone
03
and Home address
Equipment Type
Range
GE or HP
04
Default GE
Indoor Fan Operation
Range
GA or EL
05
Default GA
Minimum Off Time
Range
1 to 9 minutes
06
Default 0
Minimum Run Time
07
Range
1 to 9 minutes
Default 0
Maximum allowable heating setpoint
Range
60 to 85F
08
Default 85
Option
Description
Minimum allowable cooling setpoint
Range
55 to 80F
09
Default
65F
Heat/Cool Setpoint Differential
Range
2 to 6F
10
Default
2F
Stage 1 Temperature Differential
Range
1 to 4F
11
Default
1F
Stage 2 Temperature Differential
Range
1 to 10F
12
Default
3F
Stage 3 Temperature Differential
Range
1 to 12F
13
Default
5F
Staging Time
14
Range
On or Off
Default
Off
Staging Time When 14 = On
Range
15 - 30 (1 Minute Increments)
15
Default
15
Calibrate Temperature
Range
NA
16
Default
NA