36 / 52

Prerequisites for the initial commissioning

NOTICE
When wiring Bosch Rexroth CDI cables with a diameter of 7.4 mm, observe the following
bending radii:
Radius (when bended once while routing): 4 × cable diameter
Minimum bending radius (when moved permanently): 8 × cable diameter
Optimum bending radius (when moved permanently): 12.5 × cable diameter
Operation breakdown due to mechanical forces on the CDI cables.
Avoid mechanical stress (tensile, compressive, torsional and lateral forces) caused by plugs to
the RJ45 socket.
Malfunctions caused by using inappropriate cables.
Use only cables listed in the section "Accessories"
11

Commissioning

11.1
Prerequisites for the initial commissioning
Mounted control cabinet PC (PR31, PR4x)
Mounted multi-touch display DE
Control cabinet PC and multi-touch display with a voltage supply of DC 24 V
Video and USB connection set up:
CDI+ connection (RKB008)
or
Displayport cable und USB cable (RKB0063/RKB0019)
Bosch Rexroth AG
Material damages to electronics due to missing functional earth!
Ensure that the functional earth is connected, as otherwise the electronics
can be destroyed by a potential difference between the operating display and
the control cabinet PC if the voltage supply is interrupted to only one device
and established again. A direct connection of the functional earth between
the operator display and the control cabinet PC is optimal. If the functional
earth is connected to a neutral point, the display has to be connected to this
neutral point as well.
ctrlX HMI DE0015, DE0021