Water Connection - Miele PFD 102 i Installations Plan

Hide thumbs Also See for PFD 102 i:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13

Water connection

Water inlet
The dishwasher must only be connected to fully vented pipework.
A brief increase in the water pressure can damage components of
the dishwasher.
The quality of the incoming water must correspond to the drinking
water specification of the country in which the dishwasher is being
operated.
The dishwasher must be connected to the water supply in strict ac-
cordance with current local and national water authority regulations. It
can be connected to cold or hot water supplies. Connecting the dish-
washer to a hot water supply will reduce programme running times.
For short programme running times, dynamic water pressure of at
least 200 kPa is also required.
UK installation requirements:
The double check valve supplied with this product must be installed
between the stopcock and the water inlet hose.
Screw the double check valve onto the stopcock. Then screw the
water inlet hose with the water protection system onto the thread of
the double check valve.
If a stopcock is not available, only a qualified installer may connect
the dishwasher to the mains water supply.
The stopcock should remain accessible once the dishwasher has
been installed so that the water supply can be shut off whenever the
appliance is not in use.
en - Installation notes
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pfd 103 sci1160504011605050

Table of Contents