Keyboards; Electronic Coffee Box; Programming; Pc = Calculated Programming - Electrolux CLASSIC 1 Service Manual

Hide thumbs Also See for CLASSIC 1:
Table of Contents

Advertisement

on and the boiler level is set automatically. The water-intake
indicator blinks to show that the boiler is filling.
Heating:
When the water-intake indicator stops blinking, put the switch
on position 2 to start the heating process. When the correct
temperature has been reached, the steam pressure is
approximately 0.9 to 1 bar [0.09 to 0.1 MPa].
H.2

Keyboards

H.2.1

Electronic coffee box

1
7
6
1. Safety level control (by LED)
2. Continu/stop icon
3. Coffee icon (depends option chosen)
4. Coffee icon (depends option chosen)
5. Coffee icon (depends option chosen)
6. Coffee icon (depends option chosen)
7. Display
H.3

Programming

3
6
The icons from
to
can be programmed. The multiple
doses (1, 2 or 3 cups ) are calculated automatically from the
programming of one of them on each box:
• Set the machine switch to Position 0.
2
• Keep the icon
pressed and put again the machine on.
Display shows Pn then Pc and Pr by pressing several times the
2
key
.
H.3.1

Pc = Calculated programming

• Insert a filter-holder (with coffee) into the unit.
• Install cups.
Display shows Pc.
2
Select the dose to be programmed (2c for
3
6
to
example).
Start the infusion cycle.
2
Press again to stop when the amount of
2
coffee desired is correct.
Display of the corresponding digital value
(from 00 to 99).
• Repeat operation at 3 for the other doses (2C for example)
H.3.2

Pn = Digital programming

Quick programming without coffee and/or values carried
forward on other units.
Display shows Pn.
2
Select the dose to be programmed.
3
6
to
Display the digital value of the selected
2
dose.
Increase the value.
6
Reduce the value.
3
Memorize the new value.
2
Repeat operation at 4 for the other doses.
2
5
4
3
H.3.3

Pr = Manual programming

Same proceeding as in calculated programming Pc.
• The manual programming doesn't calculate the other doses
(1, 2 or 3 cups), only the programmed dose is modified.
• Caution: any new programming (Pn or Pc) cancel ALL
previous programmed values.
• Wait until the program mode is automatically inactivated
(from 10 to 15s), or switch OFF and ON again the machine.
H.4

Configuration of different keyboards

H.4.1

2-cup units (type d2)

1
7
6
1. Safety level control (by LED)
2. Continu/stop icon
3. 2 large cup icon
4. 1 large cup icon
5. 2 small cup icon
6. 1 small cup icon
7. Display
H.4.1.1 Use and doses to programme
4 doses of coffee and 1 Continuous / Stop manual function are
available. During the infusion, the display indicates:
or
= 1 or 2 small cups
or
= 1 or 2 large cups
= Continuous / Stop
At any time, you can change the selection by pressing another
icon. The dosage is automatic but the infusion can be stopped
manually by pressing the Continuous / Stop icon.
Programming: as the multiple doses are calculated automati-
cally, two programming only are necessary (1c or 2c) and (1C
or 2C).
H.4.1.2 Configuration parameters
dn / dt
For the automatic calculation of multiple
doses:
dn = normal dose
dt = dosing with "Torino" kit
C0 / C1 / C2
timed for the infusion time:
C0 = no timer
C1 = display of the infusion time
C2 = display of dynamic time
A0 / A1
Authorization to programme:
A0 = programming prohibited
A1 = programming authorized
After switching on, the display shows, in order, the following
information:
• the version number of the electronic memory: eg. r1
• the type of unit: D2
• the active operating parameters: eg. dn, CO, A1
H.4.1.3 Modification of the configuration of parameters
• Shut down the appliance (0/1 switch).
2
5
4
3
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Classic 2Classic 3

Table of Contents