Install Free Air Vented Drain Lines - Cleveland OEB-6.20 Installation And Maintenance Instructions Manual

Combi electric models
Hide thumbs Also See for OEB-6.20:
Table of Contents

Advertisement

DEATH, INJURY, EQUIPMENT and PROPERTY DAMAGE will result from improper
installation of drain outlet lines.
The following restrictions and requirements are critical to the safety of personnel and equipment,
and must not be violated under any circumstances:
Do not connect the Combi drain connection to any drain material that cannot sustain 140
Do not connect drains from any other equipment to the drain line of the Combi.
Do not connect the drain outlet extension line directly into a floor drain or a sewer line.
The drain line must be free air vented, have gravity flow from the Combi, and terminate
outside the perimeter of the Combi.
Improper installation of drain outlet lines voids the Combi warranty.

4. Install Free Air Vented Drain Lines

Furnishing and installing drain lines is the responsibility of the Owner/Installer.
a. The drain lines must be installed in compliance with the Basic Plumbing Code of the Building
Officials and Code Administrators International, Inc. (BOCA), and the Food Service Sanitation
Manual of the Food and Drug Administration (FDA) and any other applicable national, state, or
local codes and regulations.
b. Do not install the Combi directly over a drain. Steam rising up out of the drain will adversely
affect operation, hamper cooling air circulation, and damage electrical and electronic
components.
c. The total length of pipe and number of bend fittings required to reach the open drain determines
the pipe size used to extend the drain line to an open drain.
1) If the drain outlet extension requires 6 feet or less of pipe, and no more than two elbows are
required, 2 inch pipe and fittings are acceptable.
2) If the drain outlet extension requires 6 to 12 feet of pipe, or requires three elbows, then 2½
inch pipe and fittings are required.
3) The drain line must have gravity flow from the Combi drain outlet to floor drain.
4) Do not install a trap in the drain line.
d. Free air venting requires minimum 1" clearance between the end of the drain line and the top of
the floor drain.
e. Do not connect the Combi drain directly to drains or to the plumbing of any other equipment
f.
Refer to Figure 2-12: Run (do not connect) the Combi drain from the Combi as described below:
1) Use Drain Kit, Cleveland Range Part No. C3416730. See Figure 2-12 A
2) Cut the 2" (50 mm) tubing to length.
3) Run the 2" tubing of appropriate type to the drain outlet.
4) Leave a minimum 1" clearance between the end of the drain line and the top of the floor drain.
DANGER
14