shed onto the push bar holders (Figure 2/Item 3)
and secured as shown above in Figure 9. Then
attach the power cable to the push bar (Fig. 10/
Item A) using the cable clips (Fig. 2/Item 18). Now
you can select the push bar height in three steps
from 93.5 to 115.5 cm (Figure 7/Item A).
Important.
The handle height may only be adjusted within
the marked range.
Press in the long handle and secure in the
desired position using the quick clamping
function (Figure 7/Item B)
Important.
Always set the identical handle height on both
sides.
Use the cable clips to align the cable in ac-
cordance with the long handle
(Figure 10/Item A)
Mounting the grass basket (see Figs. 11 to 13)
First, plug the left (Fig. 2/Item 21) and right (Fig. 2/
Item 20) part of the housing together as shown in
Figure 11. Then plug the top part of the housing
(Fig. 2/Item 19) onto the already mounted parts
(Figure 12). Before you fi t the grass basket you
must ensure that the motor is switched off and the
blade is not rotating. Lift the ejector fl ap (Fig. 13 /
Item A) with one hand. With the other hand, hold
the grass basket by the handle and hook it in from
above (Fig. 13).
Filling level indicator of the grass collector
The grass collector is equipped with a fi lling level
indicator (Fig. 2/Item 24) which is opened by the
air current that the lawn mower generates during
operation. If the fl ap closes during mowing, the
grass collecting device is full and must be emp-
tied. To ensure the proper functioning of the fi lling
level indicator, the holes under the fl ap must be
kept clean and open.
Adjusting the cutting height
Important.
Adjust the cutting height only when the engine is
switched off and the power cable has been dis-
connected.
Before you begin to mow, check to ensure that the
blade is not blunt and that none of the fasteners
are damaged. To prevent any imbalance, replace
blunt and/or damaged blades. To carry out this
check, fi rst switch off the motor and pull out the
power plug.
Anl_SA_RG_EM_1536_HW_SPK8.indb 24
Anl_SA_RG_EM_1536_HW_SPK8.indb 24
GB
The cutting height is adjusted as follows (see
Fig. 14):
1. Push the lever (A) outwards.
2. Set the lever (B) to the desired cutting height.
3. Release the lever (A) and check that it is se-
curely seated in the lock.
Reading off the cutting height
The cutting height can be set between 25-75 mm
in 6 intervals, and can be read off on the scale
(Fig. 14/C).
Power supply
The lawn mower can be connected to any light
socket-outlet with a 230 Volt alternating current.
However, the socket outlet must have an earthing
contact protected by a 16 A circuit breaker. Addi-
tionally, a residual current device (RCD) circuit-
breaker with max. 30 mA must be used!
Power cable for the device
Please only use power cables that are not dama-
ged. The total length of the power cable should
not exceed 50 meters; going beyond this distance
will reduce the power output of the electric motor.
The power cable must have a cross-section of 3
x 1.5 mm. The insulating sheath of lawn aerator
power cables is frequently damaged.
Some of the causes for this are:
Cuts caused by running over the cable
Pinching when the power cable is dragging
under doors and pulled through windows.
Cracking due to old age of the insulation
Kinking by improperly fastening or guiding the
power cable
The power cables must, at the very minimum, be
of type HO5RN-F and 3-stranded. The cable type
must be printed somewhere on the power cable.
Only purchase power cables that are marked!
Plugs and socket couplers for the power cables
must be made from rubber and splash-proof.
There is a limit to how long power cables can be.
Longer power cables require larger conductor
cross-sections. Power cables and connecting li-
nes must be regularly checked for damage. Ensu-
re that the lines are switched off before checking
them. Completely unwind the power cable. Also
check power cable entry points, plugs and socket
couplers for kinks.