Rear Panel

Rear Panel
SWITCHED 1
MAX10A
,2400W
220-240V~50/60Hz
1. AC OUTLET (SWITCHED 1, 2, 3)
This is the AC power output terminal. AC power is output if the power switch in the front panel is pressed
ON or activated remotely PD-6359A. AC power is to sequentially output according to the BY PASS setting
switches, and please refer 3. BY PASS setting switch for detail explanation in this regard.
2. AC OUTLET (UNSWITCHED)
It is the terminal which AC power is supplied all the times, and it connects the devices which power should
not be off.
3. BY PASS SETTING SWITCH
The switch that sets delay time upon which AC power at SWITCHED 1, 2, 3 is output in sequence. The
setting method of delay time is referred to as the following table upon which AC power is to be output by the
interval of delay time at SWITCHED 1, 2, 3. The order of output of AC Power is SWITCHED 3>SWITCHED
2> SWITCHED 1
Ex) If BY PASS setting switch is all OFF position, then AC power is output from SWITCHED 3 and then after
2 sec., AC power is output from SWITCHED 2. At 2 sec later after AC power output from SWITCHED 2,
then AC power is output from SWITCHED 1. If PD-6359A is turned off, AC power output stops in reverse
order. If 3 of BY PASS setting switch is ON position, AC power is to output simultaneously from SWITCHED
1
2
SWITCHED 2
MAX10A ,2400W
SWITCHED 3
MAX10A ,2400W
220-240V~50/60Hz
220-240V~50/60Hz
TOTAL MAX 20A, 4800W
10
4
UNSWITCHED
MAX3A ,720W
220-240V~50/60Hz
(AMP ONLY)
(RACK ONLY)
MAX25A
SWITCHED DC OUT 24V
SWITCHED DC OUT 24V
MAX5A
TOTAL MAX 5A
12
9
POWER DISTRIBUTOR
5
6
3 7
IN
OUT
LINK
TERM
LOAD
OPEN
EMERGENCY
ADDRESS
BY PASS
OFF
ON
1 2 4 8
16
1 2 3 4
MAX5A
UNSWITCHED
REMOTE IN
DC OUT 24V
MAX5A
H
C
GND
G G
N
L
AC INPUT 220-240V~50/60Hz,24A,5800W
8
11
PD-6359A