Micom RM500 Owner's Manual

500w hf-ssb rack-mount continuous duty transceivers
Hide thumbs Also See for RM500:

Advertisement

Quick Links

MICOM RM500/RM500R
500W HF-SSB Rack-Mount
Continuous Duty Transceivers

Table of Contents

Introduction................................................................................................................... 1
Description .................................................................................................................... 2
General..................................................................................................................... 2
Equipment Versions .................................................................................................. 3
Main Features ........................................................................................................... 3
Major Accessories ..................................................................................................... 4
Performance Specifications ............................................................................................ 5
Main Technical Characteristics .................................................................................. 5
Accessories Connectors ............................................................................................. 6
Ordering Options...................................................................................................... 7
Familiarization with Equipment...................................................................................... 7
RM500 Front Panel ................................................................................................... 7
RM500R Front Panel................................................................................................. 9
RM500/RM500R Rear Panel ..................................................................................... 9
Equipment Installation ................................................................................................. 11
Installation Planning Guidelines............................................................................... 11
Preparations for Installation ..................................................................................... 12
Installation Procedure - Basic Radio ........................................................................ 13
Installation Procedure - Radio with PPS Option ...................................................... 13
Operation.................................................................................................................... 16
General................................................................................................................... 16
Preparations for Operation...................................................................................... 16
Operating Instructions ............................................................................................. 16
Bypassing the 500W Amplifier Section .................................................................... 16

Introduction

The MICOM RM500 (ordering option G160) and RM500R (ordering option G179) are 500W HF-SSB
rack-mount continuous duty transceivers, part of the MICOM-3 line of HF-SSB radio sets.
This manual covers the installation and operation of the RM500/RM500R transceivers. The manual
covers only procedures specific to the RM500 and RM500R; the other procedures, which are
common to the whole MICOM-3 product line, are described in the "Owner's Guide,
MICOM-3E/3T/3R HF-SSB Transceivers", Publication 6886867J01, and in the other applicable
MICOM-3 Supplements that cover optional features.
6888882V03
Owner's Guide
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RM500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Micom RM500

  • Page 1: Table Of Contents

    Bypassing the 500W Amplifier Section ..............16 Introduction The MICOM RM500 (ordering option G160) and RM500R (ordering option G179) are 500W HF-SSB rack-mount continuous duty transceivers, part of the MICOM-3 line of HF-SSB radio sets. This manual covers the installation and operation of the RM500/RM500R transceivers. The manual covers only procedures specific to the RM500 and RM500R;...
  • Page 2: Description

    TO ORDER – VISIT General The MICOM RM500 and RM500R are 500W HF-SSB continuous duty radio sets. Figure 1 shows a general view of a typical 500W transceiver (the RM500R). Figure 1. RM500R, General View RM500 and RM500R expand the MICOM-3 product line by offering higher transmit power and thus longer reach, and improved communications under bad propagation conditions and/or strong interference.
  • Page 3: Equipment Versions

    Thus, the RM500 and RM500R will always attempt to transmit at the maximum safe power, even in case of mismatch. Special circuits protect the RM500 and RM500R against overheating and various types of malfunctions. In case a critical problem is detected, the protection circuits are activated and bypass the internal 500W power amplifier: in this case, the MICOM-3 transceiver is directly connected to the antenna.
  • Page 4: Major Accessories

    AMD (Automatic Message Display) for free and pre-set text messages. A proven family of radio products • RM500 and RM500R are members of the MICOM transceiver family – fixed and mobile stations – covering the long-range wireless communication needs of thousands of organizations worldwide.
  • Page 5: Performance Specifications

    Performance Specifications Main Technical Characteristics This section presents the main technical characteristics of the RM500 and RM500R. For a listing of the additional performance specs, refer to the “Owner’s Guide, MICOM-3E/3T/3R HF-SSB Transceivers”, Publication 6886867J01, and to the applicable MICOM-3 Supplements that cover the optional features available on your radio set.
  • Page 6: Accessories Connectors

    PTT and CW control lines, audio and baseband lines for external equipment, auxiliary power output, serial RS-232 asynchronous data interfaces, and additional dedicated handshaking and control lines. The functions supported by the serial data interfaces are determined by the RM500/RM500R software. Table 1. 25-Pin Accessories Connector, Pin Functions Designation...
  • Page 7: Ordering Options

    Familiarization with Equipment RM500 Front Panel The front panel of the RM500 includes a standard MICOM-3 control panel, and the additional items identified in Figure 2. For a description of the MICOM-3 control panel, refer to the “Owner’s Guide, MICOM-3E/3T/3R HF-SSB Transceivers”, Publication 6886867J01;...
  • Page 8 Table 2. RM500 Front Panel Indicators (Cont.) Indicator Function TEMP Amplifier overheat indicator: lights when the internal temperature is too high. Usually, this occurs when the air intake or exhaust vents are accidentally obstructed, prolonged exposure to direct sun radiation, or excessive ambient temperatures.
  • Page 9: Rm500R Front Panel

    Handset Figure 3. RM500R Front Panel RM500/RM500R Rear Panel Figure 4 shows the rear panel of the RM500 and RM500R. The functions of the various items are explained in Table 3. Table 3. RM500/RM500R Rear Panel Items Item Description...
  • Page 10 Table 3. RM500/RM500R Rear Panel Items (Cont.) Item Description Function TX OUT Connector BNC RF output connector, for connection of unfiltered RF transmit signal to the optional pre/post-selector (PPS) TUNER CONTROL Connection of control signals to the optional pre/post-selector (PPS)
  • Page 11: Equipment Installation

    Power Requirements The RM500/RM500R requires AC power at a nominal voltage of 110 or 220 VAC, 50/60 Hz. The RM500/RM500R will automatically select the appropriate voltage range. The AC power consumption during high-power transmission is up to 2 kW.
  • Page 12: Preparations For Installation

    Cooling RM500/RM500R units are cooled by internal fans. Air is taken in through the front panel vent, and discharged toward the rear. Therefore, make sure that sufficient free space is available around the equipment to enable free air flow. Do not stack equipment units: leave at least 1U free above and below the RM500/RM500R.
  • Page 13: Installation Procedure - Basic Radio

    RM500/RM500R with option G65 and the PPS are shown in Figure 5. When the G65 option is installed, the PPS is controlled by the RM500/RM500R through serial and parallel ports and is automatically inserted by the RM500/RM500R in the signal path in accordance with the operating mode: •...
  • Page 14 During self-test, the PPS automatically switches to the bypass mode: in this mode, RF signals pass directly through the PPS, without filtering, and therefore does not interfere with system operation. The PPS also switches to the bypass mode when the RM500/RM500R frequency is outside the PPS operating range, 1.60 to 29.99 MHz.
  • Page 15 DC IN AC POWER PARALLEL I/O SERIAL I/O +12/24 VDC ANTENNA EXC OUT PA IN RADIO Serial Control Cable Parallel Control Cable ACC-J1 ACC-J3 RX IN TX IN TX OUT RX OUT TUNER CONTROL ACC-J2 ACC-J4 REMOTE CONTROL 110/220VAC RF OUT To Antenna Figure 5.
  • Page 16: Operation

    Bypassing the 500W Amplifier Section The internal 500W amplifier section of the RM500/RM500R can be permanently bypassed. In this case, you can still transmit at a power of up to 125W using the capabilities of the MICOM-3 transceiver which is part of the RM500/RM500R.

This manual is also suitable for:

Rm500r

Table of Contents