Control Features; Overall Control Dimensions - DART Controls 530B Series Instruction Manual

Variable speed dc control
Table of Contents

Advertisement

INPUT VOLTAGE SELECTION SWITCH - Switch selectable between 115 VAC and 230 VAC input.
MIN SPEED - (Minimum speed) Allows adjustment of the motor speed when the speedpot is set at minimum. This permits the user
to eliminate the "Deadband" on the main speed control, permitting zero calibration. Clockwise rotation of the "MIN" trimpot
increases output VDC.
ACCEL - (Acceleration) Allows adjustment of the motor acceleration from a minimum of 0.3 seconds to a maximum of 12 seconds.
The -15A option extends the maximum acceleration time to 30 seconds.
DECEL - (Deceleration) Allows adjustment of the motor deceleration from a minimum of 0.6 seconds to a maximum of 12 seconds.
The -15A option extends the maximum deceleration time to 30 seconds.
MAX SPEED - (Maximum speed) Allows adjustment of the motor speed when the speedpot is set at maximum (CW). This permits
the user to eliminate the "DEADBAND" of the speedpot, providing full speed at maximum rotation. Rotation of the "MAX" trimpot
in the clockwise direction increases maximum output VDC.
I.R. COMP - (Speed Regulation) Allows adjustment of the circuitry that
controls the speed regulation of the motor. This feature controls
armature speed by changing the armature voltage to compensate
for increased or decreased motor loading. Clockwise rotation of the
"I.R. COMP" trimpot will increase gain compensation.
CUR. LIM. - (Current Limit) Provides protection from excessive arm-
ature current by limiting the maximum armature current the control
can provide. This enables adjustment of the maximum torque the
motor can deliver. Set Current Limit (CUR. LIM.) at 125% of the rated
motor current. Clockwise rotation of the "CUR. LIM." trimpot increas-
es the torque (current) the control will provide.
TACH INPUT SELECTION - Factory set at 3V per 1000 RPM, jumper
selectable (JU3) to 7V per 1000 RPM. Refer to "Tach Feedback"
section in "Control Modifications" for more information.
TERMINAL STRIP P1 - Barrier type terminal strip provides for connec-
tion of AC lines, motor leads, motor field (if necessary), and earth
ground.
TERMINAL STRIP P2 - Barrier type terminal strip provides for connec-
tion of speed potentiometer and any accessories and/or jumper
wires which control the drive.
RELAY - (Power Interrupt Relay's) Available only on the "RC" and the
"RE" versions, the relay's permits the switching of AC power with a
low current signal. For the "RE" version, the relay's will not allow start
up after power failure without manually restarting.

OVERALL CONTROL DIMENSIONS

SERIES HOUSING

CONTROL FEATURES

9.00
7.50
"C" and "RC"
DIMENSIONS
7/32 DIA.
(4 SLOTS)
TOP VIEW
MIN
ACCEL DECEL MAX IR COMP
OVER CUR OUT
-1
AMP REF
-2
POT LO
-3
POT WIPER
-4
POT HI
-5
SPARE
-6
REV 1
-7
REV 2
-8
-9
+TACH
PILOT LAMP
-10
STOP
-11
COMMON
-12
-13
START
P2
INPUT VOLTAGE
SELECTION SWITCH
0.20
6.30
6.70
3
CUR LIM
TACH INPUT
SELECTION
+7
+3V
JU3
PROVIDES SUPPORT
AND TRIGGERING FOR
OPTIONS
RELAY
RELAY
RELAY
AC FUSES
-1
-2
-3
-4
-5
-6
-7
GND AC AC
+A
-A
-F
+F
2.00
END VIEW
P3
P1

Advertisement

Table of Contents
loading

Table of Contents