Important Note! Before disconnecting old control box, make note
of each wire color and the corresponding terminal connection.
Caution – To reduce the risk of electric shock, do not remove cover. No user-serviceable parts
inside. Refer servicing to qualified service personnel.
1. Determine the AC supply voltage and frequency in your country. The US, Canada, Japan, Taiwan
and South America are generally 117 VAC 60 Hz. Europe, Africa, Australia and Asia (except above
mentioned) are generally 230 VAC 50 Hz. Your power company will advise. Ensure the supplied wall
plug power supply voltage has the same input voltage as your household supply (±10%). If not,
contact your dealer.
2. Plug the power supply into the controller and the household supply. Observe the digital diagnostic
display. It should display:
60H (or 50H in 50 Hz countries)
HH1 (to use with the supplied handheld remote control)
If the above are not correct refer to Appendix A to change.
3. Disconnect the wall plug supply at the wall outlet. Connect the cables between the controller and
drive unit.
Strip Ends 1/2"
Red
4. Reconnect the AC supply to the controller. After 5 seconds it will switch off. Switch back on by pressing
any key on the front panel or handheld remote control. Perform a synchronization by pressing the sync
button on the front panel. This takes slightly over one minute. The unit may now be operated from the
front panel using the up and down controls.
5. Digital Compass. This feature operates as follows:
The display is 000 to 360 degrees where
000 is North (fully CCW viewed by a bird)
090 is East
180 is South
270 is West
360 is North (fully CW viewed by a bird)
Black
Outer
1"
Sleeving
Green
Terminals Connections
Green Wire #1 to #1
Black Wire #2 to #2
Red Wire #3 to #3
18VAC
1 AMP
WIDE
WIRE
The exclamation point indicates the presence of
important operating and maintenance (servicing)
instructions in the literature accompanying the
appliance.
4
Model 9537
CAUTION
UNIT MUST BE WIRED
CORRECTLY. SEE OWNER'S
GUIDE. CLASS 2 WIRING
MAY BE USED.