Caution: be careful, as these are very fragile connectors!
2.
Remove all the fixation screws [1] and connector [2] from the IR board control unit.
3.
Remove the IR lens, IR board from the DECO_REAR_COVER.
When defective, replace the whole unit.
3.2.4 Small Signal Board (SSB)
Caution: it is mandatory to remount all different screws at their original position during re-assembly. Failure to do so may result in damaging the SSB.
1.
Unplug all connectors [2] from the SSB.
2.
Remove all the fixation screws [3] from the SSB.
3.
The SSB can now be shifted from side connector cover, then lifted and taken out of the I/O bracket.