Cecilware Supercut-NB Operating And Maintenance Manual page 8

Vegetable cutter
Table of Contents

Advertisement

LEVER WHEN LIFTED
(BEYOND THE BLOCK POINT)
LEVER WHEN
LOWERED SENSOR
B on
the functioning of the machine should the cover be removed
and that allows for the volontary start of the
replace the discs) (Fig. n°3A),
machine (
pushing the "l" button)
position, adequately clamped with the specific hinged clamps of the
steel lid and handle of the aluminium lid
STEEL COVER
Fig. n°3 - Mechanical safety device
COVER
POSITION OF SENSOR
HINGED CLAMPS
STEEL COVER
Fig. n°3A - Electrical safety device
SENSOR
Fig. n°2 - Electrical safety device
the hopper, able to block
only once the cover is in the closed
(Fig.n°3)
ALUMINIUM COVER
COVER
POSITION OF SENSOR
COVER HANDLE
ALUMINIUM COVER
8
Furthermore check that the information on
the Technical-registration plate (fig. n°19)
corresponds to the information on the
consignment
documents.
4.2.2 - T.M. TRIPHASE VEGETABLE CUTTER (400 Volt, 50 Hz)
The T.M. Vegetable cutter is supplied with an electrical lead of 5x1 mm²
(e.g. to
section; 1,5 m length.
Link the Vegetable cutter to a 400 Volt 50 Hz threephase supply network
by means of a CEI red plug, inserting a 10 A, ΔI = 0.03 A differential-
magnetothermical switch.
Ensure that the earthing network is perfectly functional.
Furthermore, check that the information on the Technical-registration plate
(
Fig. n°19
accompanying documents.
Before permanently linking the machine to the threephase supply cable,
check the rotation direction of the discs (
single pulse of the "l" (on) button immediately followed by a stop effected
by the "O" (off) button.
The blades should have an anti-clockwise rotation when looking at the
discs through the hole positioned on the press (
Should the rotation direction not be exact, invert (inside the plug) two of
the three supply wires (black and grey).
The threephase engines assembled in the Vegetable cutter may work with
both 220V threephase current, as well as with 400V threephase current.
Unless otherwise specified, the machine whould be linked to a 400 V
supply; for adjustment to a 230V threephase supply network, request the
intervention of the "ASSISTANCE SERVICE".
and
other
accompanying
) corresponds to the information on the consignment and other
-
Fig. n°20
Direction of disc rotation
17
Fig.n°19 -Technical-registration plate
.) with a
for assembly see chap. 5.1
).
Fig.n°20

Advertisement

Table of Contents
loading

This manual is also suitable for:

Supercut-wb

Table of Contents