Altitude Data Recall; Altitude Alarm - Casio Pathfinder PAG80 Operation Manual

Casio pathfinder pag80: user guide
Table of Contents

Advertisement

To set a reference altitude
1. In the Altimeter Mode, hold down E until
SET
2. Release E, and wait for four or five more
seconds until either
reference altitude value (if set) start to flash.
This is the setting screen.
3. Press C (+) or A (–) to change the current
reference altitude value by 5 meters (or 20 feet).
• You can set the reference altitude within the
range of –10,000 to 10,000 meters (–32,800
to 32,800 feet).
• Pressing A and C at the same time returns to
altitude), so the watch performs air pressure to altitude conversions
based on preset data only.
4. Press E to exit the setting screen.
Altitude graph
The altitude graph shows Altimeter Mode
measurement results.
• The vertical axis of the graph represents
altitude, and each dot stands for 10 meters (40
Altitude
feet).
Time
• The horizontal axis represents time, and the flashing dot in the rightmost
column indicates the latest measurement result. For the first three minutes,
each dot represents five seconds. After that, each dot represents two
minutes.
• An out of range measurement result or a measurement error will cause the
column of dots for that measurement to be blank (skipped).
Altitude Differential Pointer
While a measurement operation is being performed in the Altimeter Mode, the
altitude differential pointer indicates the difference between the current
altitude and the last measured altitude.
Foot values
Meter values
Altitude differential pointer
Points to 9 o'clock for
differentials outside the
range of ±15 meters/49 feet.
Altitude differential examples
in the illustration are indicated
in 10-meter/33-foot steps.
• Altitude differential is indicated in the range of ±15 meters, in 1-meter units.
• Altitude is calculated and displayed using meters as the standard. Altitude
can also be read in feet units as shown in the illustration.
To turn display of the altitude differential pointer on and off
1. In the Altimeter Mode, hold down E until
SET
2. Release E, and wait for four or five more
seconds until either
l
reference altitude value (if set) start to flash.
This is the setting screen.
3. Press D twice to display the pointer on/off
setting screen.
4. Press C to toggle display of the altitude
differential pointer on (
(
OFF
5. When the setting is the way you want, press
E to exit the setting screen.

Altitude Alarm

The altitude alarm sounds for about five seconds when the current altitude
matches a preset value during an altitude measurement operation. You can
press any button to stop the alarm after it starts to sound.
The altitude alarm sounds only while the Altimeter Mode's Altitude Screen is
on the display. It does not sound while the watch is in another mode or while
another Altimeter Mode screen is on the display.
Example
If you set the altitude alarm at 130 meters, it sounds when you pass the 130-
meter mark on your way up and on your way back down.
Operation Guide 2894
appears in the upper display area.
OFF
or the current
OFF
(no reference
Current altitude greater
than most recent
measured altitude
Current altitude less
than most recent
measured altitude
appears in the upper display area.
OFF
or the current
ON
displayed) and off
displayed).
To set the altitude alarm
1. In the Altimeter Mode, hold down E until
SET
2. Release E, and wait for four or five more
seconds until either
reference altitude value (if set) start to flash.
This is the setting screen.
3. Press D once to display the altitude alarm
setting.
4. Press C (+) or A (–) to change the current
altitude alarm value by 5 meters (or 20 feet).
• You can set the altitude alarm value within
Altitude alarm value
the range of –10,000 to 10,000 meters
(–32,800 to 32,800 feet).
• Pressing A and C at the same time resets
the altitude alarm value to
5. Press E to exit the setting screen.
To turn the altitude alarm on and off
1. In the Altimeter Mode, hold down E until
SET
Altitude alarm on indicator
2. Release E, and wait for four or five more
seconds until either
reference altitude value (if set) start to flash.
This is the setting screen.
3. Press D once to display the altitude alarm
setting.
4. Press B to toggle the altitude alarm on (
and off (
5. Press E to exit the setting screen.
• An altitude alarm on indicator appears on the
Current On/Off status
Altimeter Mode's Altitude Screen while the
altitude alarm is turned on. This indicator does
not appear on any other screen or in any other
mode.

Altitude Data Recall

Use the Data Recall Mode to view altitude periodic records currently in
memory, as well as the current session record and the altitude historical
record. Altitude data records are created and stored in the Altimeter Mode.
Data Screens
The following explains the contents of each of the screens that appear in the
Data Recall Mode.
Note
• While the periodic record, high altitude, or low altitude screen is displayed,
the bottom part of the display alternates between the measurement date
(month and day) and measurement time at 1-second intervals.
Periodic
record
indicator
Altitude
Periodic Records
Periodic records show only data for the last save session performed with the
watch. There can be up to 40 periodic records in memory.
Current Session Record Contents
The following data items show the contents of the current session record.
Data Type
Screen Name
MAX
High Altitude
Highest altitude reached during the
recalled session.
Low Altitude
MIN
Lowest altitude reached during the recalled
session.
Total Ascent
ASC
Total cumulative ascent during the recalled
session.
Total Descent
DSC
Total cumulative descent during the
recalled session.
REL
Relative Altitude
Relative change in altitude during the
Change
recalled session.
appears in the upper display area.
OFF
or the current
O
.
appears in the upper display area.
OFF
or the current
ON
OFF
).
Alternates at
1-second intervals.
Recording time
Recording date
(Hour : Minutes)
(Month – Day)
Description
)
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2894