Continuity Testing
Continuity is indicated at less than 270k of resistance.
GFCI Testing
Check the GFCI Receptacle user manual for more information.
Always contact a qualified electrician to resolve wiring problems.
Operate the Push Button on the GFCI Receptacle. If the GFCI circuit
does not trip, the receptacle is not operating properly.
To test the functionality of a Ground Fault Circuit Interrupter receptacle,
apply leads to the hot and ground terminals for 7 seconds.
If the GFCI receptacle is wired properly, power to the circuit
will go out and the ET200 will stop indicating voltage.
If the GFCI receptacle is wired improperly, power to the circuit
will remain and the ET200 will continue to indicate voltage.
To resolve an issue, contact a qualified electrician.
Battery Replacement
Batteries are not required for visual voltage indication.
1. Remove test leads from voltage source.
2. Unscrew battery cover and replace 3xAAA batteries.
WARRANTY
This product is warranted to be free from defects in materials and workmanship
for a period of two years from the date of purchase. During this warranty period,
Klein Tools has the option to repair or replace or refund the purchase price of
any unit which fails to conform to this warranty under normal use and service.
This warranty does not cover damage which occurs in shipment or failure which
results from alteration, tampering, accident, misuse, abuse, neglect, or improper
maintenance. Batteries and damage resulting from failed batteries are not
covered by warranty. A purchase receipt or other proof of original purchase date
will be required before warranty repairs will be rendered.
Any implied warranties, including but not limited to implied warranties of
merchantability and fitness for a particular purpose, are limited to the express
warranty. Klein Tools shall not be liable for loss of use of the instrument or other
incidental or consequential damages, expenses, or economic loss, or for any
claim or claims for such damage, expenses or economic loss.
Some states or countries laws vary, so the above limitations or exclusions may
not apply to you. This warranty gives you specific legal rights, and you may also
have other rights which vary from state to state. If your Klein product requires
repair or for information on how to exercise your rights under the terms of this
warranty, please contact Klein Tools at 1-800-553-4676.
CLEANING
Clean the instrument by using a damp cloth. Do not use abrasive cleaners or
solvents.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period of
time. Do not expose to high temperatures or humidity. After a period of storage
in extreme conditions exceeding the limits mentioned in the Specifications
section, allow the instrument to return to normal operating conditions before
using it.
DISPOSAL / RECYCLE
Caution:
This symbol indicates that equipment and its accessories
shall be subject to a separate collection and correct disposal.
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street
Lincolnshire, IL 60069
1-800-553-4676
www.kleintools.com
Rev. 05/10
Instruction
Manual
ET200
ENGLISH
AC/DC
VOLTAGE
TO 600V
CONTINUITY
FUNCTION
WORKLIGHT
LIGHT, VIBRATION, SOUND INDICATORS
CAT IV 600V SAFETY RATING
MODERN SOLID-STATE DESIGN
www.kleintools.com
139575T

Advertisement

loading

Summary of Contents for Klein Tools ET200

  • Page 1 Any implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the express warranty. Klein Tools shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss.
  • Page 2: General Specifications

    Negative DC Voltage Dangerous levels 60 seconds, with a cool-off time of at least 5 minutes. The Klein Tools ET200 is a solid-state electrical tester. It measures AC/DC AC Voltage Double Insulated Class II Tester will turn on automatically when voltage is applied.
  • Page 3 Todas las garantías implícitas, incluyendo pero sin estar limitadas a las garantías implícitas de comerciabilidad e idoneidad para un propósito específico, están limitadas a la garantía expresa. Klein Tools no será responsable por la pérdida de uso del instrumento u otros daños incidentales o emergentes, gastos o pérdida económica, ni por cualquier reclamo o reclamos por dichos daños, gastos o...
  • Page 4: Especificaciones Generales

    Niveles peligrosos de 277 V debe ser inferior a 60 segundos, con un tiempo de enfriamiento de por lo menos 5 minutos. El ET200 de Klein Tools es un probador eléctrico de estado sólido. Con aislamiento doble Tensión de CA Mide tensión de CA/CC, prueba continuidad y cuenta con una luz de trabajo...
  • Page 5: Garantie

    Toutes garanties implicites, y compris, entre autres, les garanties implicites de qualité marchande et d’adéquation à un but particulier, sont limitées à la garantie expresse. Klein Tools n’assumera aucune responsabilité au titre de la perte d’utilisation de l’instrument ou pour d’autres dommages, frais ou pertes économiques secondaires ou accessoires, ou en cas de réclamation ou de...
  • Page 6 Appuyez sur le bouton montrant une ampoule électrique au-dessus du logo que les sondes sont toujours connectées à une source de tension. Klein Tools pour basculer entre l’activation et la désactivation de la lampe Prenez des précautions lorsque vous travaillez avec des tensions de travail.