Technician Setup
Occupancy Models Only
Tech Setup Steps
When using the Occupancy model
the installer can choose to utilize
Local
the occupancy sensor to set back
Occupancy
the room temperature while it is
Sensor
not being occupied.
When the occupancy sensor is
Duration of
turned on you have the ability
Occupancy
to set how long the thermostat
will go into occupancy mode
(Only displayed if
everytime a person is sensed.
Local Occupancy
Sensor is ON)
Set the cooling temperature and
fan operation that you would like
Occupied
the system to be while the space
Cool Setting
is being occupied.
(Only displayed if
Local Occupancy
Sensor is ON)
Set the heating temperature and
Occupied
fan operation that you would like
the system to be while the space
Heat Setting
is being occupied.
(Only displayed if
Local Occupancy
Sensor is ON)
Set the cool temperature and fan
operation that you would like the
Unoccupied
system to be while the space is
Cool Setting
unoccupied.
(Only displayed if
Local Occupancy
Sensor is ON)
15

Network Specifications

Wireless Network Specifications
The thermostat will attempt to pair with the first Basemodule it
"hears". Do not attempt to create more than one "pair" at the same
time in the same place.
To ensure paring success, place the T731W/O within a few feet of
the Base module while pairing. Once paired, the signal strength
tech menu can be used to ensure a robust wireless connection.
Placing either device in or around large metal objects can severely
degrade the wireless range.
The wireless network will automatically recover in the event of a
power loss or temporary signal loss.

Network Capabilities

A single basemodule can support up to 7 remotes.
If more than one Tthermostat is connected to a base module, the
system will control to the last interaction
Thermostat units will require up to 60 seconds to reflect changes
elsewhere in the network.
A base module paired with another base module will work as a
"repeater". It will match the relay state of the main base module.
Note:
Changes or modifications not expressly approved by the manufacturer could
void the user's authority to operate the equipment.
19
LCD Will Show
Adjustment Options
ON
OF(OFF)
0F
OCC SENSOR
30 = 30 minutes, 1 = 1 hour,
2 = 2 hours, 3 = 3 hours, 4
8
= 4 hours, 5 = 5 hours, 6 =
6 hours, 7 = 7 hours, 8 =8
hours, 9 = 9 hours, 10 = 10
OCC LENGTH
hours, 11 = 11 hours, and 12
= 12 hours.
Full temperature ange
defined by setpoint limits.
75
First adjust the temperature
using the + and – buttons.
OCC COOL
Use the Fan button to change
the fan operation.
Full temperature ange defined
by setpoint limits.
70
First adjust the temperature
using the + and – buttons.
OCC HEAT
Use the Fan button to change
the fan operation.
Full temperature ange defined
by setpoint limits.
83
First adjust the temperature
using the + and – buttons.
Use the Fan button to change
UNOCC HEAT
the fan operation. normal high
intensity all the time.
Default
Tech Setup Steps
Set the heat temperature and fan
Unoccupied
operation that you would like the
Heat Setting
OF
system to be while the space is
(Only displayed if
unoccupied.
Local Occupancy
Sensor is ON)
Set the level of sensitivity of
the occupancy sensor. Lowering
8
the sensitivity will cause the
sensor to respond only to larger
movements.
Occupancy
78˚
Sensitivity
Setting
(Only displayed if
Local Occupancy
70˚
83˚
Specifications
Thermostat
The display range of temperature ... 41˚F to 95˚F (5˚C to 35˚C)
The control range of temperature.... 44˚F to 90˚F (7˚C to 32˚C)
Load rating.................................................1 amp per terminal, 1.5 amp
Swing (cycle rate or differential) ...... Heating is adjustable from 0.2˚ to 2.0˚
Power source ...........................................18 to 30 VAC, NEC Class II, 50/60 Hz
Operating ambient ............................... 32˚F to +105˚F (0˚C to +41˚C)
Operating humidity .............................. 90% non-condensing maximum
Dimensions of thermostat ................. 4.7"W x 4.4"H x 1.1"D
Frequency ................................................ 916 MHz
Base Module
Load rating ............................................... 1 amp per terminal, 1.5 amp
Power source ...........................................18 to 30 VAC, NEC Class II, 50/60 Hz
Operating ambient ............................... 32˚F to +150˚F (0˚C to +65˚C)
Operating humidity .............................. 90% non-condensing maximum
Technician Setup
Occupancy Models Only
LCD Will Show
Adjustment Options
Full temperature ange
defined by setpoint limits.
62
First adjust the temperature
using the + and – buttons.
UNOCC COOL
Use the Fan button to
change the fan operation.
High Sensitivity:
This is the most sensitive
setting and
will detect very slight mo-
tions. This is the recommend-
ed setting because it will work
well for nearly all applications.
Will detect any movement.
HI
Medium Sensitivity:
This is the medium sensitive
setting and can be used
without pets setting it off.
Low Sensitivity:
This is the least sensitive
setting and can
be used in areas of major or
large motions. This will not be
set off by pets, small children,
or people more than 20' from
the sensor location.
maximum all terminals combined
Cooling is adjustable from 0.2˚ to 2.0˚
for hardwire
Battery power from 2 AA Alkaline
batteries
maximum all terminals combined.
Default
62˚
HI
16
Specifications
20