ERROR CODE DISPLAY AND SOLUTIONS
Error Code
BF
EE1
EE2
EE4
EEF
EE5
EE6
EE7
EE9
EEA
If you are receiving error codes above, check the machine for dust. If you continue to receive error codes,
please contact Royal Sovereign's Service Center at 1-800-397-1025.
9
Reason
Wheels running without feeding bills
Suspect note is flagged due to UV error
Suspect note is flagged due to MG error (no
magnet)
Suspect note is flagged due to half size error
(partly ripped or folded)
The left (right) counting sensor is dirty or
broken
Two bills are counted as one/inaccurate
counting
Suspect note is flagged due to MG error (to
much magnetic presence on the bill)
Bill is slanted/not inserted properly
Suspect note is flagged due to bill width
being larger than 75 mm
Suspect note is flagged due to chain note
error
(CONTINUED)
Solutions
Press reset and feed bills again.
Remove first bill from the stacker,
then continue counting.
Remove first bill from the stacker,
then continue counting.
Remove first bill from the stacker,
then continue counting.
Clean the sensor or contact Royal
Sovereign to replace sensor.
Tighten the tension adjustment
screw clockwise.
Remove first bill from the stacker,
then continue counting.
Remove first bill from the stacker,
then continue counting.
Remove first bill from the stacker,
then continue counting.
Remove first bill from the stacker,
then continue counting.