Summary of Contents for Tripp Lite B110-SP-CAT-OD2
Page 1
Tripp Lite: tripplite.com/support Ce manuel est disponible en français sur le site Web de Tripp Lite : tripplite.com/support Русскоязычная версия настоящего руководства представлена на веб-сайте компании Tripp Lite по адресу: tripplite.com/support WARRANTY REGISTRATION Register your product today and be automatically entered...
Optional Accessories • N224-Series Cat6 Plenum-Rated Solid-Core Bulk Cable • N046-000 Punch Down Installation Tool Mounting Instructions 1. Locate the mounting holes on the bottom of the enclosure, as shown in Figure 1. Figure 1 2. Securely mount the bottom portion of the enclosure to the desired outdoor location.
• Maximum cable distance between B110-SP-CAT-OD2 and equipment is 328 ft. (100 m). • For best protection performance, the total cable distance in the installation should not exceed 328 ft. (100 m). • The B110-SP-CAT-OD2 must be grounded to function properly.
Page 5
Installation Protecting Edge-Of-Network Equipment This installation protects your edge equipment from surge, lightning or ESD damage. To protect both the source and edge equipment, refer to section Protecting Edge-Of-Network Source and Equipment in this guide. Note: Use standard size Cat5e, Cat6 or Cat6a cables that feature a wire gauge of 23/24 AWG.
Page 6
Installation 3. Insert both the grounding wire and the bare-wire end of the category cable in the enclosure, making sure it is inserted on the “cable end” side.
Page 7
1. Then, tighten the cap securely onto the cable gland. 5. Using a punch down tool (such as Tripp Lite’s N046-000, sold separately), connect the bare wire to the color-coded board inside the enclosure.
Page 8
Installation 7. Once both bare wires are connected, secure the PCBA board to the enclosure using the included mounting screws. Then, attach the grounding wire to the available screw on the PCBA board. Note: Make sure you connect your source to the cable end and your PoE-compliant device to the equipment end.
Page 9
B110-SP-CAT-OD2 units in your application. A B110-SP-POE can be installed instead of a second B110-SP-CAT-OD2 to protect the source if the second unit will be installed indoors. Note: Use standard size Cat5e, Cat6 or Cat6a cables that feature a wire gauge of 23/24 AWG.
Page 10
Installation 2. In order to protect both the source and edge equipment, the two B110-SP-CAT-OD2 units need to be wired cable- end to cable-end as shown below. 328 ft. (100 m)
Specifications Input / Output Connectors RJ45 Female ESD Protection 15kV (Air), 8kV (Contact) Lightning Protection 10kA (8/20μs) / 20kV (8/20μs) Surge Reaction Speed < 1ns Operating Temperature Range -40°F to 158°F (-40°C to 70°C) Storage Temperature Range -40°F to 194°F (-40°C to 90°C) Relative Humidity Range 0 to 95% RH,...
Tripp Lite warrants its products to be free from defects in materials and workmanship for a period of two (2) years from the date of initial purchase. Tripp Lite’s obligation under this warranty is limited to repairing or replacing (at its sole option) any such defective products.