READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, disable the ventilator by cover-
ing the solar panel with cardboard or disconnecting the wires
from the motor terminals (note wire locations when disconnect-
ing).
3. Installation work must be done by a qualified person(s) in ac-
cordance with all applicable codes and standards, including
fire-rated construction codes and standards.
4. If removing an existing 120 VAC powered attic ventilator, use
only a qualified person(s) to remove any electrical wiring in
accordance with all applicable codes and standards.
5. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment manufac-
turer's guidelines and safety standards such as those published
by the National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air Condition-
ing Engineers (ASHRAE), and the local code authorities.
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
TOOLS AND MATERIALS REQUIRED
r
Slotted Screwdriver
r
Drill
r
1/4" Drill Bit
r
Sabre Saw or Keyhole Saw
r
Hammer
r
Ruler / Tape Measure
r
Pencil, Marker or Scribe
r
Utility Knife
r
Pry Bar (to remove roofing nails)
r
5/16" Socket and Extension
r
Roofing Cement
r
Galvanized #10 x 1" Pancake Head Wood Screws
MODELS 345RSOBK • 345RSOWW
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. This unit has an unguarded impeller. Do not use in locations readily
accessible to people or animals.
4. This ventilator operates when the solar panel is exposed to sun
light. To reduce risk of injury while installing, servicing or clean-
ing unit, cover the solar panel with cardboard or disconnect the
wires from the motor terminals (note wire locations when discon-
necting).
5. The recommended open air inlet for this ventilator is 2 square
feet. The best location for these air intake vents are under the
eaves with direct access to the attic. Failure to provide these in-
takes could cause natural-draft gas appliances to backdraft.
6. Your attic fan installation will create a screened opening into
your attic space. During a heavy rain storm there could be a light
spray of rain into this attic space. This is a normal condition with
all attic ventilators and will not cause any damage to the struc-
ture. We recommend that you do not store any valuable articles
directly under the fan opening in the roof.
7. This ventilator is intended for roof installation. Broan Models 353,
345GOBK & 345GOWW Gable Mount Ventilators are available
for side wall applications.
8. The plastic ventilator dome and base may be painted with high
quality paint. Follow the paint manufacturer's recommendations
for acrylic and ABS plastic as appropriate. Take care to avoid
getting paint on the solar panel.
9. This ventilator includes a permanently lubricated motor. Do not
oil or disassemble.
10. The installation instructions contained in this document are only
a recommendation and individual professionals may have their
own methods of installation. If your roof has an existing warranty,
installation of this product by anyone other than those who in-
stalled the roof may jeopardize any future warranty claim. Please
check with the original installer of your roof if this is a concern.
11. When working with asphalt shingles in cold weather (below
40
F), take care to avoid damage to the shingle edges and cor-
o
ners.
12. For installations in climates where cold weather condensation
is not a concern, Broan Model CWT45 thermostat is available.
It disconnects power to the motor when the temperature drops
below 50
F. Power is applied to the motor when the temperature
o
reaches 61
F.
o
Page 1

Advertisement

loading

Summary of Contents for Broan 345RSOBK

  • Page 1 Engineers (ASHRAE), and the local code authorities. 7. This ventilator is intended for roof installation. Broan Models 353, 6. When cutting or drilling into wall or ceiling, do not damage 345GOBK & 345GOWW Gable Mount Ventilators are available electrical wiring and other hidden utilities.
  • Page 2: Installation

    MODELS 345RSOBK • 345RSOWW Page 2 INSTALLATION Note: This ventilator is capable of replacing an existing 120 volt powered attic ventilator. Only a qualified per- son should remove any electrical wiring in accordance with local codes and standards. 4. Separate the ventilator dome from the ventilator base by removing the four (4) sheet metal screws.
  • Page 3 MODELS 345RSOBK • 345RSOWW Page 3 7. From the roof side, using the guide hole as the center point, use a nail and string to scribe a 16-1/2” diameter 10. Drill a large starting hole for the sabre saw just inside of circle on the shingles.
  • Page 4 MODELS 345RSOBK • 345RSOWW Page 4 13. Apply a large bead of roofing cement in the molded 15. Using a good grade of roofing cement material, seal groove on the bottom side of ventilator base. Make sure shingles and all screw heads. DO NOT seal the bottom the arrow on the ventilator base is pointed toward the edge of the ventilator base.
  • Page 5 MODELS 345RSOBK • 345RSOWW Page 5 REMOTE SOLAR PANEL 21. Connect the red wire to the positive motor terminal and the black wire to the negative motor terminal. Tape or INSTALLATION tie extra wire to prevent contact with the fan blade.
  • Page 6: Service Parts

    MODELS 345RSOBK • 345RSOWW Page 6 SERVICE PARTS Model Model 345RSOBK 345RSOWW Description (Black) (Weathered Wood) 77001317 77001318 Solar Panel Assembly 77001320 77001321 Dome Assembly CWT45 CWT45 Thermostat (Optional) 79020041 79020041 Fan Blade w/ Set Screw 79080082 79080082 Motor, DC...