Graco HYDRA-SPRAY 218-058 A Instructions-Parts List Manual
Graco HYDRA-SPRAY 218-058 A Instructions-Parts List Manual

Graco HYDRA-SPRAY 218-058 A Instructions-Parts List Manual

23:1-ratio monark pump

Advertisement

Quick Links

INSTRUCTIONS-PARTS LIST
This manual
contains
WARNINGS and INSTRUCTIONS
READ AND RETAIN FOR REFERENCE
INDEX
..........................................................
..............................................
.........................................................
Operation
Parts Drawing and List, Model 218-058
Parts Drawina and List. Model 218059
......................................................
..............................................
......................................
......................................
.............................................
GRACO INC. P.O. Box 1441 MINNEAPOLIS, MN 554401444
IMPORTANT
......................................
...........
.................................
...................
...................
..........................
Back Cover
Back Cover
2
4
7
8
10
11
12
13
14
307-619
Rev D
SUPERSEDES C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HYDRA-SPRAY 218-058 A and is the answer not in the manual?

Questions and answers

Summary of Contents for Graco HYDRA-SPRAY 218-058 A

  • Page 1: Table Of Contents

    Parts Drawing and List, Model 218-058 ....Parts Drawina and List. Model 218059 ............Accessories ......How To Order Replacement Parts ..........Pump Dimensions ........Mounting Hole Layout ........Technical Data Back Cover ..........Warranty Back Cover GRACO INC. P.O. Box 1441 MINNEAPOLIS, MN 554401444...
  • Page 2 FOR PROFESSIONAL USE ONLY. OBSERVE ALL WARNINGS. before Read and understand all instruction manuals operating equipment. Safety G e n e r a l ALWAYS have the tip guard in place on the spray gun while This equipment generates very high fluid pressure. Spray from spraying.
  • Page 3 solvent pails used when flushing, according to local Static electricity is created by the high velocity flow of fluid code. Use onlymeralpails. which are conductive. Do not through the pump and hose. every pan of the spray equip- place the pail on a non-conductive surface, such as paper ment is not properly grounded.
  • Page 4: Warnings

    To help ensure that Your svstem suits vour needs. con- the pre-adjusted setting. A pump which operates too tact your Graco representative for professional design fast can be seriously damaged. assistance.
  • Page 5 Starting and Adjusting the Pump Fill the wet-cup one-half full with Graco Throat Seal Li- quid (TSLI before operating the pump to help prolong the packing life. See Fig 2. See ACCESSORIES on page 12 to order TSL.
  • Page 6: Troubleshooting Chart

    .WARMING Pressure Relief Procedure To reduce the risk of serious bodily injury, in- 5. Hold a metal part of the gun firmly to the side a grounded metal pail, and trigger the gun to the skin, or injury from moving parts, always relieve pressure.
  • Page 7: Removing Air Motor Or Displacement Pump

    'ROBLEM CAUSE SOLUTION Restricted line or inadequate air 'ump fails to operate Clear, increase air Open, clean (be sure to Insufficient air pressure; closed or use air filter) clogged air valves, etc. Refill; purge all air from Exhausted fluid supply pump and fluid linas Service air motor Damaged air valving mechanism;...
  • Page 8: Displacement Pump Repair

    (120). If you can't remove the sleeve easily, contact your nearest Graco Factory Branch or Service Depot. Reassembling the,_Pump Coat the displacement roTand inside of the sleeve with oil.
  • Page 9 Connect the pump and air motor and remount them. Tighten the packing nut just enough to stop leakage, but no tighter. Fill the packing nutlwet-cup one-half full of Graco Throat Seal Liquid before operating the pump. NOTE: If the grounding wire was disconnected before servicing, be sure to reconnect before operating the pump.
  • Page 10 Model Series PARTS LIST Monark Pump, Standard REF PART DESCRIPTION NO. NO. PIN, cotter LOCKNUT O-RING: Buna-Nm ROD, tie air (see PUMP, displacement 1 0 1 1 2 4 Series A Includes items 1 0 1 GUIDE, ball STUD, piston 207-084 ROD, displacement 1 0 4...
  • Page 11 PARTS LIST Model 218469. Series P . l Pump, Monark Severe-Duty Displacement Pump REF PART DESCRIPTION NO. NO. ‘12 PIN, cotter LOCKNUT O-RING: 164-722 ROD, MOTOR, air PUMP, displacement 1 0 1 1 2 4 Includes items Series A 1 0 1 170-257 GUIDE, ball STUD, piston...
  • Page 12: Accessories

    15 ft (4.5 m) Ig AIR LINE FILTER (7.5 m l Ig psi 114 bar) MAXIMUM WORKING PRESSURE (15.2 m) Ig GRACO THROAT SEAL LIQUID Non-evaporating solvent for wet cup 1 quart (0.95 liter) 1 gallon (3.8 liter) GAL. SUCTION KIT...
  • Page 13: How To Order Replacement Parts

    ACCESSORIES GROUNDED NYLON FLUID HOSE PUMP RUNAWAY VALVE 215362 Urethane Cover Shut off air supply to the pump if the pump accelerates beyond the pre-adjusted setting due to an empty supply container, interrupted fluid supply to the pump, or ex- cessive cavitation.
  • Page 14: Pump Dimensions

    P UMP DIMENSIONS. Fluid Overall Pump 27.50 in. 1114 MOUNTING HOLE 4.6 in...
  • Page 15 307-619...
  • Page 16: Technical Data

    BREACH OF WARRANTY MUST BE BROUGHT WITHIN TWO YEARS OF THE DATE OF SALE. GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PAR- PURPOSE. WITH RESPECT TO ACCESSORIES. EQUIPMENT. MATERIALS, OR COMPONENTS SOLD BUT NOT MANUFAC- TURED BY GRACO.