2. Press the AC Power ON/OFF Button and wait for a solid white light.
NOTE:
Make sure the AC power plug is fully plugged into the AC output port before pressing the AC Power
ON/OFF Button.
A flashing white light indicates safety checks are in progress. If you see a flashing red light, the device
you connected is rated for greater than 65 watts and cannot be powered using the powerstation go
rugged AC.
The powerstation go rugged AC will automatically power off after 30 minutes of inactivity. While jump
starting your vehicle, you cannot charge your electronic devices using the USB or AC output ports and
you cannot charge the powerstation go rugged AC.
Condition
The power ON/OFF
button flashes red
The powerstation go rugged
AC shuts off unexpectedly
The powerstation go
rugged AC displays a blue
or red "TEMP" indicator
Charging an electronic device using USB output port
1. Connect the USB Type-C tip of the supplied USB Type-C Cable into the USB Type-C input of your electronic
device and connect the Standard USB end of the supplied USB Type-C cable into either one of the
powerstation portable battery USB 5V/2.4A Output ports.
Figure 6
2. Turn on the USB charging by pressing the USB Power ON/OFF Button on the powerstation go rugged AC.
NOTE:
If your electronic device does not have a USB Type-C Input, the powerstation go rugged AC is also
compatible with the charging cable provided with your electronic device. To use, plug the Standard
USB end of the cable into the 5V/2.4A USB Output port located on the powerstation go rugged AC.
The powerstation go rugged AC USB charging feature will automatically power off after 30 minutes
of inactivity.
Potential Cause
Electronic device is rated
at greater than 65 watts.
The powerstation go rugged
AC is not sufficiently charged
to power the connected
electronic device.
The powerstation go rugged
AC is not sufficiently charged
to power the connected
electronic device.
The powerstation go rugged
AC has detected a low or high
temperature condition.
Solution
Only electronic devices
rated at 65 watts or less
can be used with the
powerstation go rugged AC.
Recharge the powerstation
go rugged AC.
Recharge the powerstation
go rugged AC.
Disconnect the powerstation
go rugged AC and allow unit
to acclimate to temperature
operating range (14°F to
122°F) (-10°C to 50°C).