Xylem ODO RTU User Manual page 36

Optical dissolved oxygen & temperature sensor
Table of Contents

Advertisement

Probe Assemblies
NOTE:
The ODO and OBOD sensor caps come pre-installed on the following probe assemblies, with calibration coefficients
of the sensor cap pre-loaded into the probe at the factory.
YSI Item #
Description
Optical Dissolved Oxygen and Temperature Probes
627350-1
ODO RTU Probe Assembly, 1m
627350-4
ODO RTU Probe Assembly, 4m
627350-10
ODO RTU Probe Assembly, 10m
627350-20
ODO RTU Probe Assembly, 20m
627350-30
ODO RTU Probe Assembly, 30m
627350-50
ODO RTU Probe Assembly, 50m
627350-100
ODO RTU Probe Assembly, 100m
Optical Dissolved Oxygen, Conductivity, and Temperature Probes
627370-1
ODO RTU Probe Assembly with Conductivity, 1m
627370-4
ODO RTU Probe Assembly with Conductivity, 4m
627370-10
ODO RTU Probe Assembly with Conductivity, 10m
627370-20
ODO RTU Probe Assembly with Conductivity, 20m
627370-30
ODO RTU Probe Assembly with Conductivity, 30m
627370-50
ODO RTU Probe Assembly with Conductivity, 50m
627370-100
ODO RTU Probe Assembly with Conductivity, 100m
Replacement ODO Sensor Caps, Standards, and Accessories
YSI Item #
Description
Replacement ODO Sensor Caps
627180
Replacement ODO Extended Warranty Sensor Cap (only compatible with ODO/T and
ODO/CT probe assemblies)
Calibration Standards
065270
Conductivity standard, 1000 μmhos/cm (quart, glass); ideal for fresh water
065272
Conductivity standard, 10000 μmhos/cm (quart, glass); ideal for brackish water
065274
Conductivity standard, 100000 μmhos/cm (quart, glass); ideal for supersaturated sea water
060907
Conductivity standard, 1000 μmhos/cm (box of 8 individual pints, plastic); ideal for fresh water
060906
Conductivity standard, 1413 μmhos/cm, ±1%, 0.01 M KCl (box of 8 individual pints, plastic)
060911
Conductivity standard, 10000 μmhos/cm (box of 8 individual pints, plastic); ideal for brackish water
060660
Conductivity standard, 50000 μmhos/cm (box of 8 individual pints, plastic); ideal for sea water
Other Accessories
603076
Flow cell for ODO/CT cables (requires single port adapter; 603078)
603078
Adapter required for ODO/CT flow cell (603076)
603056
Flow cell mounting spike
627195
Calibration cup for ODO/CT cable assembly (included with all ODO/CT cables)
605978
Weight, 4.9 oz
603062
Cable management kit (included with ODO/CT cables 4, 10, 20, and 30-meters long; and ODO/T cables 4,
10, 20, and 30-meters long)
Accessories
36

Advertisement

Table of Contents
loading

This manual is also suitable for:

627379-01

Table of Contents