Utilitech 148137 Manual

Utilitech 148137 Manual

Pedestal sump pump
Table of Contents

Advertisement

Available languages

Available languages

ATTACH YOUR RECEIPT HERE
Serial Number
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 1-866-994-4148, 7:30 a.m. - 5:00 p.m., EST, Monday - Friday.
AB171077
Purchase Date
1
PEDESTAL SUMP PUMP
ITEM #1964546
MODEL #148137
Español p. 9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 148137 and is the answer not in the manual?

Questions and answers

Summary of Contents for Utilitech 148137

  • Page 1 ITEM #1964546 PEDESTAL SUMP PUMP MODEL #148137 Español p. 9 ATTACH YOUR RECEIPT HERE Purchase Date Serial Number Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-866-994-4148, 7:30 a.m. - 5:00 p.m., EST, Monday - Friday.
  • Page 2: Package Contents

    PACKAGE CONTENTS DESCRIPTION QUANTITY Pump SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate, or install the product. NOTE: Pumps with the “UL” Mark and pumps with the “US” mark are tested to UL Standard UL778. CSA certified pumps are certified to CSA Standard C22.2 No.
  • Page 3 WARNING • ELECTRICAL SHOCK ALERT. Before installing this product, have the electrical circuit checked by an electrician to ensure proper grounding. All electrical installations must conform to the National Electric Code and all local codes. • ELECTRICAL SHOCK ALERT. Connect this product to a properly-grounded 115 volt circuit equipped with a Ground Fault Circuit Interrupter (GFCI) device.
  • Page 4: General Pump Information

    PREPARATION Estimated Installation Time: 20 minutes Materials required for assembly: Sump basin, inlet piping, discharge piping (PVC, poly pipe or galvanized steel), check valve, and 2-step PVC glue system (primer and sealer). SPECIFICATIONS PERFORMANCE IN GALLONS PER MINUTE MODEL AMPS 0 FT.
  • Page 5: Installation Instructions

    INSTALLATION INSTRUCTIONS 1. Make sure the sump basin is cleared of any debris or sediment, then place pump (A) on a hard surface inside the basin. 2. Connect the discharge pipe, fittings and check Discharge pipe IL2042 valve (not provided) to pump (A) discharge and ttings according to local codes.The discharge pipe should be the same size as the discharge of...
  • Page 6: Care And Maintenance

    4. Test the operation of the pump by pouring water into the sump basin. IL2045 5. If the lower rod stop is positioned 8 in. from Top Float Rod Stop the top of the rod, the pump will turn on at approximately 10 in.
  • Page 7: Troubleshooting

    TROUBLESHOOTING DANGER RISK OF ELECTRIC SHOCK. Always disconnect power source before attempting to install, service, or maintain the pump. Never handle a pump with wet hands or when standing on wet or damp surface or in water. Fatal electrical shock could occur. PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION...
  • Page 8: Warranty

    WARRANTY This product is warranted for one year from the date of purchase or two years from the date of manufacture, whichever occurs first. Subject to the conditions hereinafter set forth, the manufacturer will repair or replace to the original consumer, any portion of the product which proves defective due to defective materials or workmanship.
  • Page 9 ARTÍCULO #1964546 BOMBA DE SUMIDERO DE PEDESTAL MODELO #148137 ADJUNTE SU RECIBO AQUÍ Número de serie ¿Preguntas, problemas, piezas faltantes? Antes de volver a la tienda, llame a nuestro Departamento de Servicio al Cliente al 1-866-994-4148, de lunes a viernes de...
  • Page 10: Información De Seguridad

    CONTENIDO DEL PAQUETE DESCRIPCIÓN CANTIDAD Bomba INFORMACIÓN DE SEGURIDAD Lea y comprenda completamente este manual antes de intentar ensamblar, usar o instalar el producto. NOTA: Las bombas con la marca “UL” y con la marca “US” se prueban para cumplir con los estándares UL778 de UL.
  • Page 11 ADVERTENCIA • ALERTA DE DESCARGA ELÉCTRICA. Antes de instalar este producto, haga que un electricista revise su circuito para asegurarse de que la puesta a tierra sea adecuada. Todas las instalaciones eléctricas deben cumplir con el Código Nacional de Electricidad (NEC, por sus siglas en inglés) y con todos los códigos locales. •...
  • Page 12: Especificaciones

    PREPARACIÓN Tiempo de instalación estimado: 20 minutos Materiales necesarios para en ensamblaje: Recipiente para sumidero, tubería de entrada, tubería de descarga (PVC, polietileno o acero galvanizado), válvula de retención y sistema de adhesivo para PVC de 2 pasos (cebado y sellado). ESPECIFICACIONES RENDIMIENTO EN GALONES POR MINUTO MODELO...
  • Page 13: Instrucciones De Instalación

    INSTRUCCIONES DE INSTALACIÓN 1. Asegúrese de que el recipiente del sumidero esté libre de suciedad y sedimentos y luego coloque la bomba (A) sobre una superficie dura dentro del recipiente. 2. Conecte la tubería de descarga, los accesorios Tubo de descarga IL2042 y la válvula de control (no se incluye) para y conectores...
  • Page 14: Cuidado Y Mantenimiento

    4. Para probar el funcionamiento de la bomba, vierta agua en el recipiente del sumidero. IL2045 5. Si el tope de la varilla inferior se coloca a Tope superior de la 20,32 cm de la parte superior de la varilla, la varilla del flotador bomba se encenderá...
  • Page 15: Solución De Problemas

    SOLUCIÓN DE PROBLEMAS PELIGRO RIESGO DE DESCARGA ELÉCTRICA. Desconecte siempre la fuente de alimentación antes de intentar instalar, reparar, reubicar o realizarle mantenimiento a la bomba. Nunca manipule la bomba con las manos mojadas ni cuando esté parado sobre una superficie húmeda o en el agua. Podría ocurrir una descarga eléctrica fatal. PROBLEMA CAUSA POSIBLE ACCIÓN CORRECTIVA...
  • Page 16 PROBLEMA CAUSA POSIBLE ACCIÓN CORRECTIVA Cuando la 1. El impulsor, la entrada de la bomba o 1. Extraiga la bomba del recipiente y bomba arranca, la tubería de descarga pueden estar limpie el impulsor, la entrada de la el fusible se obstruidos.