White Mini-Seis III Pro Operating Manual page 40

Seismograph
Table of Contents

Advertisement

Command Description
FL
Returns a list of the valid event and histogram files in memory.
The format of the output is as follows:
/<year>-<month>-<day>-<hour>-<minute>-<second>-
<id>.<ext>, where year is the 4-digit year, month is the 2-digit
month, day is the 2-digit day, hour is the 2-digit, 24-hour
representation of the hour, minute is the 2-digit minute, and
second is the 2-digit second at which the record was started; id
is the 4-digit file ID, and ext is "proevt" for waveform-type files
and "prohst" for histogram-type files. Note that invalid files
(ones not closed properly) are skipped.
Example waveform: /2016-12-08-11-59-23-0001.proevt
Example histogram: /2016-12-08-11-59-23-0002.prohst
FN
Returns the total number of event and histogram files in
memory.
FU
Copies the current settings to the factory defaults. Returns "OK"
when successful.
GR
Queues sending the latest automatic report for delivery in three
seconds.
HB enable
Enables or disables the daily heartbeat message and sets the
[HHMM]
time for the message. If HH and MM are omitted, the last
heartbeat time set is used (or the default, if the heartbeat time
has never been set).
If passed with no parameters and disabled, returns "0". If
enabled, returns 1 (enabled) and the hour and minute at which
the heartbeat is to be sent. Note that HH and MM must be 0-
padded.
HI interval
Get or set the histogram interval duration (hours). If passed
with no parameters, returns the current value.
NE event
Returns the summary and event data for event. If event is
invalid or blank, returns "Invalid index."
NS event
Returns the summary data for event. If event is invalid or blank,
returns "Invalid index."
RE bits
Get or set the ADC resolution. If passed with no parameters,
returns the current value.
RF
Restores the default parameters.
RI interface
Get or set the interface used for remote reporting and
heartbeats. If passed with no parameters, returns the current
value.
RM
Reset the seismograph.
Mini-Seis III Pro™ Operating Manual
Parameters
MM: 00–59 (required for
fixed mode)
none
none
none
none
Enable:
0 = Don't send daily
heartbeat messages
1 = Send daily heartbeat
messages
HHMM:
24-hour time at which to
send the daily heartbeat
message.
HH: 00–23
MM: 00–59
interval:
0–12
event:
The ID of the event for
which to get summary and
event data as indicated in
the FL command. Valid
values are 1 up to the
number of entries
returned by the FN
command.
event:
The ID of the event for
which to get summary
data as indicated in the FL
command. Valid values
are 1 up to the number of
entries returned by the FN
command.
bits:
12 = 12-bit
16 = 16-bit
none
interface:
0 = RS-232
1 = USB
none
Page 40

Advertisement

Table of Contents
loading

Table of Contents