Panasonic NA-F80GD Service Manual page 15

Table of Contents

Advertisement

Rotary
detector
Caution to put
the body B on
to the body A
1 Lay down the machine on it nothing drain hose side.
* Please spread cloth to prevent scratch on the body.
2 Remove 2 screws mounting the rotary detector.
3 Remove the connector.
1 Before put the body B on to the body A, Check if the lever of the lid switch is
not bent.
2 Pull the tub frontward, and insert the lever properly.
3 After set the body B, check condition of the lever of the lid switch.
* How to check condition of the lid switch movement.
If it is normal condition, In case to push the tub to lid switch lever side,
water amount lamp shall be indicated 67L.
15