TROUBLESHOOTING, CARE & SAFETY
Errors
Coil Error
If there is a coil error, the error icon and the coil icon is
displayed for 5 seconds before the detector automatically
powers off�

Error Troubleshooting

Error icon and coil icon are displayed, the detector turns off after 5 seconds
1.
Check that the coil connector is connected properly at the front of the control box�
2.
Check the coil cable for damage�
3.
Check the coil for visible signs of damage�
4.
Try another coil, if you have one available�
Error icon is displayed, then the detector turns off after 5 seconds
1.
Contact an authorised Minelab service centre�
Error icon is displayed, detector remains on
1.
Remove the speaker cover screw on the rear of the control box using a Phillips head screw driver�
2.
Check that the User Interface connector is connected properly to the input on the control box�
3.
If the error persists, contact an authorised Minelab service centre�
CONTENTS

System Error

If there is a system error, the error icon is displayed for 5
seconds before the detector automatically powers off�